Daikin VRV III-S RXYMQ36/48PVJU Service Manual R410A (60Hz) PDF
$95.00 Original price was: $95.00.$18.95Current price is: $18.95.
Official Daikin VRV III-S service manual for RXYMQ36PVJU & RXYMQ48PVJU (R-410A heat pump, 60Hz). Includes specs, electrical/functional parts list, refrigerant circuit, PCB layout, field settings, test operation, and detailed troubleshooting with error codes, plus wiring/piping diagrams and R-410A service precautions. Instant PDF download
Description
Daikin VRV III-S RXYMQ36/48PVJU Service Manual R410A (60Hz) PDF DOWNLOAD

Description
If youβre diagnosing or servicing a Daikin VRV III-S Heat Pump system (R-410A, 60Hz), this manual gives you the exact factory procedures for setup, control logic, diagnostics, and repairsβincluding a full error code section and wiring/piping diagrams.
β Models Covered (Outdoor Unit)
RXYMQ36PVJU
RXYMQ48PVJU
β Indoor Unit Types Listed (connectable series overview)
Includes indoor unit families such as:
Ceiling cassette (multi-flow) FXFQ
2βΓ2β 4-way cassette FXZQ
Slim duct FXDQ
Duct FXMQ
Ceiling suspended FXHQ
Wall mounted FXAQ
Floor standing FXLQ
Concealed floor standing FXNQ
π Whatβs Inside (Clean, categorized contents)
1) General Information
Model names of indoor/outdoor units
External appearance (indoor & outdoor)
Capacity range
2) Specifications
Outdoor unit specifications
Indoor unit specifications
3) Electrical & Functional Parts
Electrical/functional parts list (outdoor & indoor)
4) Refrigerant Circuit
Refrigerant circuit (RXYMQ36/48)
Functional parts layout
5) Functions & Controls (how the system operates)
Operation modes + basic control logic
Compressor PI control
EEV PI control
Fan control (cooling)
Special controls: startup, oil return, defrost, pump down residual, restart standby, stopping
Protection controls: high/low pressure, discharge pipe, inverter protection
Other controls: demand operation, heating prohibition
Indoor unit control outline (drain pump, louver controls, thermostat sensor, freeze prevention, swing flap operation)
6) Test Operation & Field Settings
Test operation procedure and power-on behavior
Outdoor unit PCB layout
Field settings from remote controller
Field settings from outdoor unit
7) Troubleshooting (big technician section)
Symptom-based troubleshooting
Troubleshooting via wired/wireless remote controller
Maintenance mode + self-diagnosis
Error code troubleshooting (A0, A1, A3, A6, A7, A9, AF, CJ, E3, E4, E5, E7, F3, U0, U2, U4, U5, UA, etc.)
Centralized control / unified controller troubleshooting
8) Appendix
Piping diagrams (outdoor & indoor)
Wiring diagrams (outdoor, field wiring, indoor)
Option list (controllers/outdoor)
Connection examples
Thermistor resistance vs temperature characteristics
Pressure sensor details
9) R-410A Service Precautions
Refrigerant handling outline
Refrigerant cylinders
Service tools guidance
π File Details
| Item | Details |
|---|---|
| Manual Name | Daikin VRV III-S Service Manual (R-410A Heat Pump 60Hz) |
| Models Covered | RXYMQ36PVJU, RXYMQ48PVJU |
| Year | June 2010 |
| PDF Quality | Clear, searchable text with diagrams/tables |
| Pages | 264 pages |
Cut diagnostic time fastβthis manual gives you the exact error code logic, field settings, wiring, and control details technicians use every day. Download instantly and get your VRV III-S system running right again.
What Our Customers Say
π Related Products
Discover more professional manuals for your equipment

Daikin SkyAir RZQ200β250C7Y1B R-410A Heat Pump Service Manual PDF

Daikin VRV Water Cooled Heat Pump / Heat Recovery (RWEYQ8β30) Service Manual β PDF

Daikin VRV III Heat Pump Service Manual RXYQ5-54PY1 R-410A System PDF
