Dräger Primus Anaesthetic Workstation Technical Documentation Service Manual PDF
$120.00 Original price was: $120.00.$33.95Current price is: $33.95.
Official Dräger Primus Anaesthetic Workstation Technical Documentation (Service Manual) PDF. Covers full function description of Primus systems: GUI/MoBi, S-Box, Patient Gas Module (PGM/PGM2), Mixer (O₂/N₂O/AIR), VGC ventilator & breathing system, power pack/UPS batteries, operating modes, alarms, and component structure. Includes step-by-step maintenance procedures (filters, PGM service, VGC seals, regulators, PCB battery) plus pneumatic components diagrams & schematics
Description
Dräger Primus Anaesthetic Workstation Technical Documentation Service Manual PDF DOWNLOAD

Description
📘 Dräger Primus Anaesthetic Workstation — Technical Documentation (Service Manual)
This is the factory technical documentation for the Dräger Primus Anaesthetic Workstation, built for qualified service technicians. It explains how the Primus is designed and how to maintain key systems—ventilation, gas mixing, patient gas measurement (PGM/PGM2), electronics/CAN communication, and the UPS/power pack—with diagrams, operating modes, and service procedures.
✅ What you’ll be able to do with this manual
Understand the full Primus component structure (GUI/MoBi, Mixer, VGC, Power Pack, PGM/PGM2, Neutral Point PCB)
Follow detailed maintenance procedures (filters, batteries, seals, pressure regulators, PCB battery replacement)
Reference pneumatic layouts, schematics, and block diagrams for accurate troubleshooting
Work with multiple configurations like PGM vs PGM2 and software version 2.n+ ventilation modes
📑 Table of Contents
General
Symbols and definitions
Notes and standards references
Function Description
General overview (medical purpose, classification, protection classes)
Primus short description: ventilator, breathing system, mixer, GUI/MoBi, options
Component structure (Neutral Point PCB, GUI, Mixer, VGC, power pack, cylinder pressure regulator)
Electronic / Interface Sections
Neutral Point PCB (signal/voltage distribution)
GUI / Monitor Control Panel (MoBi), S-Box (interface box), backplane PCB
SpO₂ sampling option
Patient Gas Module (PGM / PGM2)
PGM2 (ILCA2 + O₂ sensor variants)
PGM (IRIA + electrochemical O₂)
Operating modes (accuracy modes / standby behavior)
Calibration behavior (IRIA/ILCA2 and O₂ sensors)
PGM/PGM2 electronics (MOPS PCB, AMO boards, flow control PCB)
Mixer
Operating modes and layout
Gas inlet block (AIR, O₂, N₂O) and pressure status indicators
Pneumatic system (valves, sensors)
VGC (Ventilation & Gas Controller)
Electronics + piston cylinder unit
Pneumatic block/system and breathing system
Automatic, manual, spontaneous breathing
Ventilation modes (software 2.n+): volume mode, pressure mode, pressure support, manual/spont, etc.
Power & Other Systems
Power pack (UPS batteries, outputs, warnings)
Operating modes (cold start, standby, shutdown, safety mode, alarms)
Cylinder pressure reducer
Vaporizer
Bronchial aspirator (variants and pneumatics)
Block diagrams and pneumatic component layouts
Maintenance Procedures
Safety precautions
Rear panel removal/fitting + final check
Replace bronchial suction bacterial filter
Replace filter mat on PGM fan
Replace bacterial filter + Nafion tube in PGM (including PGM removal)
Replace filter mats (housing cover, power pack, VGC)
Replace UPS batteries (power pack removal, battery replacement)
Replace VGC seals/diaphragms (rolling seal, roller diaphragm, PEEP and MAN/SPONT diaphragms)
Replace pressure regulators (N₂O/AIR/O₂) + overhaul procedure
Replace CPU PRIMUS PCB lithium battery (mixer removal/opening/refit)
Schematics and Diagrams
Primus pneumatic components diagram
Schematics and diagrams section
Annex
Parts catalog
Test list
Technical information
📌 File Details
| Item | Details |
|---|---|
| Manual Name | Dräger Primus Anaesthetic Workstation – Technical Documentation |
| Models Covered | Primus Anaesthetic Workstation (includes PGM/PGM2 configurations) |
| Year | 2006 (Revision 6.0) |
| Manual PDF Quality | Clear factory-formatted technical documentation (procedures + diagrams) |
| Pages | 336 pages |
When you’re servicing an anaesthesia workstation, you can’t afford guesswork—this manual gives you the official procedures, diagrams, and maintenance steps to repair Primus correctly. Buy now and download instantly to get the workstation back in service fast.
What Our Customers Say
🌟 Related Products
Discover more professional manuals for your equipment


Dräger Incubator 8000 Service Manual – Inspection & Retrofit Guide (PDF)

Dräger Evita 4 Ventilator Service Manual (Maintenance, Tests, Parts) PDF