★ TRUSTED BY 321,897+ PROFESSIONALS WORLDWIDE
🏢
Trusted Business
Verified & Licensed
🛡️
Virus Free Files
100% Safe Downloads
🔒
Secure Payment
SSL Protected
Instant Delivery
Available Immediately
Sale!

GMM OPERA Swing RF Table Service Manual PDF

Original price was: $120.00.Current price is: $28.95.

Comprehensive GMM OPERA Swing service manual PDF for multi-purpose R/F tables, including OPERA Swing installation procedures, GMM RF table adjustment manual details, OPERA Swing X-ray alignment guide, multi-purpose RF table assembly instructions, GMM OPERA Swing error codes troubleshooting, and table schemes. Features setup, regulations, calibrations, and diagrams for X-ray equipment technicians. 339 pages with technical illustrations and safety notes

Instant PDF Download
Available immediately
💾
Save to Your Device
Download & keep forever
🛡️
Antivirus Scanned
100% virus-free
🌍
Trusted Worldwide
175,000+ customers

Description

GMM OPERA Swing RF Table Service Manual PDF DOWNLOAD

Description

This official GMM OPERA Swing service manual PDF is a complete guide for servicing the multi-purpose R/F (Radiography/Fluoroscopy) table OPERA Swing by General Medical Merate (GMM). Compiled under code 62305, it integrates the installation manual (code 62302, rev 01A, February 2011), adjustment manual (code 62301, rev 01, September 2009), and table schemes (code 62311, rev 01, March 2010). The document provides detailed OPERA Swing installation procedures, from unpacking and base plate fixation to assembling components like the tilting set, column stand, detector, X-ray sheath, and collimator. It emphasizes safety with typographic conventions, symbols, and warnings to prevent equipment damage or injury during GMM RF table adjustment manual tasks.

The manual supports GMM OPERA Swing error codes troubleshooting through dedicated sections on alarms, system configuration, and software management. For precise calibrations, the OPERA Swing X-ray alignment guide covers mechanical alignments, centerings, and regulations for movements like tilting, tabletop elevation, and detector positioning. Multi-purpose RF table assembly instructions include step-by-step guidance with weights, dimensions, and environmental requirements, ensuring compliance with technical features such as mains supply and room layouts.

Navigation is aided by sectional indexes and tables of contents:

  • Installation Manual Table of Contents (Page 9; neatly categorized):
SectionTitlePage
1GENERAL NOTES5
1.1Typographic conventions6
1.2Symbols of advice positioned on the equipment7
1.3Additional operation symbols8
2TECHNICAL FEATURES9
2.1Mains supply9
2.2Environmental characteristics10
2.3Weights10
3OPERA SWING DIMENSIONS11
3.1Overall dimensions11
3.2OPERA Swing diagnostic room (typical layout)14
4OPERA SWING PACKING16
4.1Packing list16
4.2Base plate packing18
4.3Packing jacks and brackets19
4.4Unpacking procedures19
5BASE PLATE FIXATION TO THE FLOOR20
6OPERA SWING ASSEMBLING23
6.1Tilting set assembling23
6.2The frame from the jack assembling24
6.3Tilting set covering27
6.4Reassemble the frame completely27
6.4.1Assembling the detector arm27
6.4.2Tabletop support positioning29
6.5Assembling the cabinet electric components30
6.6Control console placing (release with pulpit)30
6.7First steps to connect the equipment cables to the power cabinet31
6.8Equipment starting up31
6.9Column stand assembling32
6.9.1Fasten the column to the equipment32
6.9.2Cables connection33
6.9.3Electric cables connection36
6.9.4Motors enable36
6.10Detector assemble36
6.11X-ray sheath assembling38
6.12Collimator assembling40
6.13Detector grid42
6.14Tabletop assemble43
6.15Assembling the cable sheaths44
6.15.1Assembling the focal trolley cables sheath44

(Note: TOC continues with additional assembly and testing sections as per document structure.)

  • Adjustment Manual General Index (Page 77; total pages 217, each section preceded by its index):
Sec. No.Section TitlePageRev.Rev. Date
0General index60109/2009
1Setup procedure40109/2009
1.1Touch Screen Setup60109/2009
1.2Tabletop Setup Area – INSTALLATION100109/2009
1.3Tabletop DEBUG60109/2009
1.4APR Table Setup120109/2009
2Error codes and alarms140109/2009
3System configuration10109/2009
3.1Password10109/2009
3.2Language10109/2009
3.3APR path display10109/2009
3.4Touch screen use10109/2009
3.5Room configuration30109/2009
3.6Remote console20109/2009
4Regulations10109/2009
4.1Tilting80109/2009
4.2Tabletop elevation60109/2009
4.3Stand longitudinal displacement60109/2009
4.4Detector longitudinal displacement60109/2009
4.5Focal Distance60109/2009
4.6X-ray tube oscillation60109/2009
4.7X-ray tube flapping60109/2009
4.8X-ray tube transversal displacement60109/2009
4.9Detector elevation60109/2009
4.10Detector transversal displacement60109/2009
4.11Detector pivoting60109/2009
4.12Detector rotation60109/2009
4.13Grid40109/2009
4.14Collimator80109/2009
4.15Safety devices40109/2009
4.16Touch Screen calibration60109/2009
4.17Alignments and centerings120109/2009
5Motor control tool200109/2009
6Software management20109/2009
6.1Update of Touch Screen firmware00109/2009
6.2Update of S1 card firmware180109/2009
6.3Update of S5 and S6 cards firmware00109/2009
7Chains and belts adjustment00109/2009
  • Adjustment Manual Section 4 Index (Page 143; detailed regulations subset):
Section No.Section TitleRev No.Rev. Date
4.1Tilting0109/2009
4.2Tabletop elevation0109/2009
4.3Stand longitudinal displacement0109/2009
4.4Detector longitudinal displacement0109/2009
4.5Focal distance0109/2009
4.6X-ray tube oscillation0109/2009
4.7X-ray tube flapping0109/2009
4.8X-ray tube transversal displacement0109/2009
4.9Detector elevation0109/2009
4.10Detector transversal displacement0109/2009
4.11Detector pivoting0109/2009
4.12Detector rotation0109/2009
4.13Grid0109/2009
4.14Collimator0109/2009
4.15Safety devices0109/2009
4.16Touchscreen calibration0109/2009
4.17Alignments and centrings0109/2009

The table schemes section includes electrical and mechanical diagrams for reference. Ideal for OPERA Swing regulations and calibrations, this PDF ensures accurate maintenance using genuine parts and proper techniques. Original Italian draft translated to English; verify with actual equipment.

File Details

  • Manual Name: Multi-purpose R/F table OPERA Swing Service Manual
  • Models Covered: OPERA Swing
  • Year: 2009-2011
  • Manual PDF Quality: High quality with clear text, tables, illustrations, and diagrams
  • No. of Pages: 339

What Our Customers Say

★★★★★ Live reviews from customers
Loading customer reviews...
0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    🛒
    Recently Purchased
    🕒 verified order