Kikusui COS5020 / COS5021 Oscilloscope Instruction & Service Manual (1998) PDF
$110.00 Original price was: $110.00.$34.95Current price is: $34.95.
Official Kikusui COS5020 & COS5021 oscilloscope instruction/service manual (1998) in PDF. Covers 20 MHz dual-channel operation, full specifications, safety precautions, front/rear panel functions, triggering & sweep, X-Y mode, COS5021 delayed sweep/B-sweep, plus circuit description, calibration procedures, block diagram, schematics, and replaceable parts info. Instant download.
Description
Kikusui COS5020 / COS5021 Oscilloscope Instruction & Service Manual (1998) PDF DOWNLOAD

📘 Kikusui COS5020 / COS5021 Oscilloscope – Instruction & Service Manual (PDF)
This manual is a handy factory reference for operating, testing, and servicing the Kikusui COS5020 / COS5021 oscilloscopes. It includes the practical “how to use it” section (controls, triggering, sweep, X-Y mode), plus real technician content like circuit descriptions, calibration/adjustment steps, and supporting diagrams/schematics—perfect for repair benches, labs, and electronics troubleshooting.
⭐ Quick Highlights
Dual-channel, 20 MHz (-3 dB) scope with up to 1 mV/div sensitivity (×5 MAG)
Fast timebase down to 20 ns/div
COS5021 adds delayed sweep / B-sweep features
Built-in calibrator output (square wave) for probe compensation and checks
📑 Table of Contents
1) General
Description
Features
2) Specifications
3) Precautions Before Operating the Oscilloscope
Unpacking the oscilloscope
Checking the line voltage (selector plug + fuse)
Operating environments
CRT intensity precautions
Withstanding voltages of input terminals
4) Operation Method
Explanation of front panel
Explanation of rear panel
Basic operation
Dual-channel operation
ADD operation (CH1+CH2)
X-Y operation & EXT HOR operation
Triggering
Single-sweep operation
Sweep magnification
Waveform magnification with delayed sweep (COS5021 only)
Calibration of probe
5) Circuit Description
Preamplifiers
Vertical switching circuit
Vertical output amplifier
Trigger generator
A & B sweep generator
Horizontal switching circuit
Horizontal output amplifier
Z-axis amplifier
CRT control circuit
High-voltage regulator (HV generator)
Power supply circuit
Calibrator circuit
6) Calibration / Adjustment
Removing the case
DC supply voltage checks & adjustments
CRT circuit adjustments
Vertical axis adjustments
Trigger circuit adjustments
Time base adjustments
Horizontal axis (X-axis) adjustments
Appendix / Drawings / Parts
Block diagram
Circuit schematics (Vertical amplifier / Trigger & sweep / CRT & power supply)
Parts locations (boards/modules)
Semiconductor lead configuration
Replaceable parts list (COS5020 + COS5021)
Mechanical assembly drawings
🔧 Key Specs Customers Care About (great for SEO)
Vertical System
Sensitivity: 5 mV/div to 5 V/div (NORM), 1 mV/div to 1 V/div (×5 MAG)
Bandwidth: DC–20 MHz (NORM), DC–15 MHz (×5 MAG)
Input impedance: 1 MΩ / ~25 pF
Max input (CH1/CH2): 400 V (DC + AC peak)
Triggering / Sweep / Display
Trigger sources: CH1 / CH2 / LINE / EXT
Trigger modes: AUTO / NORM / SINGLE / LEVEL LOCK
Timebase: 0.2 µs/div to 0.5 s/div (A sweep), down to 20 ns/div via magnification
COS5021: delayed sweep / B-sweep functions
Calibrator (Probe Compensation)
Square wave: ~1 kHz, ~2 Vp-p output (built-in)
Power / Physical
Power: 100/115/215/230V, 50/60 Hz, ~35 VA
Weight: ~7.0 kg
Includes probe accessories (2 probes listed)
📌 File Details
| Item | Details |
|---|---|
| Manual Name | Kikusui COS5020 / COS5021 Oscilloscope Instruction Manual |
| Models Covered | COS5020, COS5021 |
| Year | 1998 |
| PDF Quality | Scanned, readable pages (manual layout + tables/diagrams) |
| Pages | 128 pages |
Get the exact factory specs, operating instructions, calibration steps, and schematics you need to keep your COS5020/COS5021 running right. Buy now and download instantly—perfect for bench troubleshooting and repairs.