★ TRUSTED BY 321,897+ PROFESSIONALS WORLDWIDE
๐Ÿข
Trusted Business
Verified & Licensed
๐Ÿ›ก๏ธ
Virus Free Files
100% Safe Downloads
๐Ÿ”’
Secure Payment
SSL Protected
โšก
Instant Delivery
Available Immediately
Sale!

Lennox VRF HE DC Inverter Units Service Manual โ€” 460V R410A PDF

Original price was: $95.00.Current price is: $19.95.

Official Lennox VRF HE Series DC Inverter Units Service Manual for 440โ€“460V R410A outdoor systems. Covers commissioning, function settings, DIP switch configuration, wiring, error codes, troubleshooting procedures, refrigerant charging, maintenance, parts replacement, pressure/temperature tables, electrical specs, circuit diagrams, and schematic drawings. Includes full model list from VEP075N432G2 to VEP960N432G2. 332-page OEM searchable PDF.

Buy now
โšก
Instant PDF Download
Available immediately
๐Ÿ’พ
Save to Your Device
Download & keep forever
๐Ÿ›ก๏ธ
Antivirus Scanned
100% virus-free
๐ŸŒ
Trusted Worldwide
175,000+ customers

Description

Lennox VRF HE DC Inverter Units Service Manual โ€” 460V R410A PDF DOWNLOAD

Description

Overview

This comprehensive Lennox VRF HE DC Inverter Units Service Manual provides complete guidance for installation verification, commissioning, diagnostics, maintenance, and after-sales service of multi-module VRF HE Series outdoor units operating on R410A refrigerant at 440โ€“460V / 3-phase / 60Hz.

The manual explains:

  • safety and service precautions

  • commissioning workflow & documentation

  • fault indication and error codes

  • detailed troubleshooting logic

  • refrigerant charging & leakage checks

  • replacement of key components

  • parts lists, exploded views & electrical drawings

It supports both basic modules and combined multi-module systems up to 96 HP.


Models Coveredย 

Basic Modules (Single Unit)

VEP075N432G2 โ€ข VEP096N432G2 โ€ข VEP120N432G2 โ€ข VEP132N432G2
VEP150N432G2 โ€ข VEP171N432G2 โ€ข VEP196N432G2 โ€ข VEP210N432G2
VEP240N432G2

Cooling capacities range from 22.4 kW to 68 kW with inverter scroll compressors (EVI).


Combined Multi-Module Units (26โ€“96 HP)

Examples include:

  • 12+14 โ†’ VEP252N432G2 (26 HP)

  • 22+22 โ†’ VEP420N432G2 (44 HP)

  • 22+24+24 โ†’ VEP690N432G2 (70 HP)

  • 24+24+24+24 โ†’ VEP960N432G2 (96 HP)

Tables include:

  • cooling & heating capacity

  • input power & rated current

  • refrigerant charge values

  • maximum connected indoor units

  • gas & liquid pipe diameters

  • weight & dimensions

(Full multi-page model tables included in Chapter 1.)


Highlighted Technical Specifications

(from Parameters Tables โ€” pp.3โ€“10)

  • Refrigerant: R410A

  • Power Supply: 440โ€“460V / 3~ / 60Hz

  • Compressor: Inverter scroll, EVI

  • Outdoor static pressure: 0โ€“110 Pa

  • Operating temperature range:

    • Cooling: -15ยฐC to 48ยฐC DB

    • Heating: -25ยฐC to 24ยฐC DB

Safety note: cooling below -5ยฐC is conditional and requires engineering approval.


Structured Contentsย 

Chapter 1 โ€” Product

  • Unit List (basic + combined modules)

  • Performance parameters & piping sizes

  • Operating temperature range


Chapter 2 โ€” Commissioning

Includes full commissioning workflow and documentation templates:

  • commissioning process & preparation tools

  • safety requirements

  • pre-commissioning checklists

  • installation verification (piping, wiring, grounding)

  • communication & controller addressing checks

  • commissioning data record forms

The checklist tables cover:

  • refrigerant pressure balance validation

  • valve leakage inspection

  • pipe length & elevation rules

  • static pressure confirmation

  • phase sequence & voltage tolerance

  • communication termination resistors


Chapter 3 โ€” Faults

  • Error indication tables

  • Fault code descriptions

  • Troubleshooting flow charts

  • Non-fault condition diagnostics (202+ pages of cases)

Covers:

  • pressure & temperature anomalies

  • compressor startup conditions

  • communication failures

  • sensor resistance & signal ranges


Chapter 4 โ€” Maintenance

Includes procedures for:

  • refrigerant leakage inspection

  • refrigerant charging methods

  • oil & piping inspection

  • pressure testing

  • key component replacement

  • exploded views & parts list (from p.304)


Appendixes

  • Temperature sensor resistance tables

  • Refrigerant pressure / temperature charts

  • Pressure sensor voltage conversion tables

  • Electrical specifications

  • Circuit diagrams

  • System schematic diagrams

  • Component name & function guide


Why This Manual is Valuable

Ideal for:

  • VRF service contractors

  • commissioning engineers

  • HVAC maintenance teams

  • facility & BMS integration technicians

It provides complete lifecycle service coverage from installation validation to advanced diagnostics.


File Details

FieldDetails
Manual NameLennox VRF HE Series DC Inverter Units Service Manual
Models CoveredVEP075N432G2 โ€” VEP960N432G2 (Basic & Combined Modules)
RefrigerantR410A
Power440โ€“460V, 3-Phase, 60Hz
Pages332 pages
FormatOEM, searchable PDF
IncludesCommissioning, faults, troubleshooting, charging, parts, circuits

 

What Our Customers Say

โ˜…โ˜…โ˜…โ˜…โ˜… Live reviews from customers
Loading customer reviews...
0
๐Ÿ›’
Recently Purchased
๐Ÿ•’ verified order