★ TRUSTED BY 321,897+ PROFESSIONALS WORLDWIDE
🏢
Trusted Business
Verified & Licensed
🛡️
Virus Free Files
100% Safe Downloads
🔒
Secure Payment
SSL Protected
Instant Delivery
Available Immediately
Sale!

Nihon Kohden Celltak MEK-6400 6410 6420 Service Manual Hematology Analyzer – PDF

Original price was: $65.00.Current price is: $15.95.

Official Nihon Kohden Celltak automated hematology analyzer service manual (Document 0634-900086B, May 2007) covering MEK-6400/6410/6420 models with C, J, K variants. This comprehensive 200-page technical manual includes specifications, troubleshooting procedures, alarm message resolution, system error diagnostics, reproducibility checks, accuracy verification, board/unit descriptions, service maintenance screens, EMC compliance, WBC/RBC/PLT measurement systems, and complete service information for qualified biomedical technicians servicing clinical laboratory hematology equipment.

Instant PDF Download
Available immediately
💾
Save to Your Device
Download & keep forever
🛡️
Antivirus Scanned
100% virus-free
🌍
Trusted Worldwide
175,000+ customers

Description

Nihon Kohden Celltak MEK-6400 6410 6420 Service Manual Hematology Analyzer – PDF DOWNLOAD

DESCRIPTION

This is the official Nihon Kohden Celltak Automated Hematology Analyzer Service Manual (Document Number 0634-900086B, Created May 10, 2007, Modified February 5, 2017) covering the complete MEK-6400/6410/6420 series with regional variants (C, J, K). This comprehensive 200-page technical manual is intended for qualified biomedical equipment technicians and provides complete maintenance, troubleshooting, calibration, and repair procedures for these automated hematology analyzers used in clinical laboratories, hospitals, medical facilities, and diagnostic centers worldwide for complete blood count (CBC) testing.

Product Overview

Nihon Kohden Celltak MEK-6400/6410/6420 Series:

The Celltak series represents Nihon Kohden’s advanced automated hematology analyzers designed for clinical laboratory blood cell counting and analysis. These sophisticated instruments combine impedance counting technology, spectrophotometric measurement, precision fluid handling, and automated sample processing to deliver accurate and reproducible complete blood count (CBC) results for patient diagnosis and monitoring in healthcare settings.

Key Applications:

  • Clinical laboratory hematology
  • Complete blood count (CBC) testing
  • Hospital laboratory diagnostics
  • Medical diagnostic centers
  • Blood bank operations
  • Research laboratories
  • Veterinary hematology
  • Point-of-care testing
  • Patient monitoring
  • Disease diagnosis and screening

Models Covered

MEK-6400 Series:

  • MEK-6400 (Base model)
  • MEK-6400C (Regional variant C)
  • MEK-6400J (Regional variant J – Japan)
  • MEK-6400K (Regional variant K – Korea)

MEK-6410 Series:

  • MEK-6410
  • MEK-6410C
  • MEK-6410J
  • MEK-6410K

MEK-6420 Series:

  • MEK-6420
  • MEK-6420C
  • MEK-6420J
  • MEK-6420K

Model Differences:

  • MEK-6400: Base model with manual sample loading
  • MEK-6410: Adds automated rinse unit (MR-640V)
  • MEK-6420: Enhanced features with automated rinse
  • Cap Pierce Unit (MS-641V): MEK-6400 only

Measured Parameters

Complete Blood Count (CBC) Parameters:

  • WBC – White Blood Cell count
  • RBC – Red Blood Cell count
  • HGB – Hemoglobin concentration
  • HCT – Hematocrit
  • MCV – Mean Corpuscular Volume
  • MCH – Mean Corpuscular Hemoglobin
  • MCHC – Mean Corpuscular Hemoglobin Concentration
  • PLT – Platelet count
  • RDW – Red Cell Distribution Width (if applicable)

Key Technical Systems

Detection Methods:

  • Impedance counting (Coulter principle)
  • Spectrophotometric measurement for hemoglobin
  • Precision dilution systems
  • Multi-channel analysis

Fluid Handling System:

  • MD-640V Combination Syringe Pump Unit
  • MP-640V Pump Unit
  • JQ-640V Inlet/Outlet Unit
  • JQ-641V/JQ-642V Valve Units
  • Precision dilution and reagent delivery

Sample Handling:

  • MS-640V Sampler Unit
  • MS-641V Cap Pierce Unit (MEK-6400 only)
  • MR-640V Rinse Unit (MEK-6410/6420 only)
  • Automated or manual sample introduction

Measurement System:

  • MC-640V Measuring Unit
  • UT-7198 MEASURING Board
  • UT-7201 HGB AMP Board
  • UT-7202 HGB LED Board
  • Precision transducers and detectors

Control Electronics:

  • UT-7192 AMP CONTROL Board
  • UT-7193 POWER Board
  • UT-7200 MIXED PUMP Board
  • UT-7205 PRINTER DRIVER Board
  • PV-641V Front Panel Unit

Comprehensive Manual Contents

DOCUMENT INFORMATION:

  • Document Number: 0634-900086B
  • Title: Automated Hematology Analyzer MEK-6400/MEK-6410/MEK-6420 Service Manual
  • Creation Date: May 10, 2007
  • Modified Date: February 5, 2017
  • Creator: PageMaker 7.0J
  • Pages: 200 pages
  • Format: A4 (595 x 842 pts)
  • PDF Version: 1.4
  • File Size: 7.0 MB

GENERAL HANDLING AND WARRANTY

General Handling Precautions:

  • Proper instrument handling requirements
  • Safety considerations
  • Professional user responsibilities

Warranty Policy:

  • Manufacturer warranty terms
  • Service coverage
  • Exclusions and limitations

Responsibilities – Professional Users:

  • Qualified service personnel only
  • Proper training requirements
  • Maintenance obligations

EMC Related Caution:

  • Electromagnetic compatibility requirements
  • Interference considerations
  • Installation environment specifications

Conventions Used:

  • Warnings: Serious bodily injury or death possible
  • Cautions: Equipment damage or injury possible
  • Notes: Additional information and tips

COMPLETE TABLE OF CONTENTS

SECTION 1: GENERAL (Pages 1.1-1.13)

Introduction:

  • Product overview
  • Intended use
  • Service policy

Specifications:

Measured Parameters, Ranges and Reproducibility:

  • Parameter specifications
  • Measurement ranges
  • Reproducibility values
  • CV (Coefficient of Variation) requirements

Standardization Analysis Method:

  • Calibration procedures
  • Reference standards

Detection Method:

  • Impedance counting principles
  • Spectrophotometric measurement
  • Measurement technology

Dilution Ratio:

  • WBC dilution specifications
  • RBC dilution specifications
  • Sample preparation

Counting Time:

  • Measurement cycle time
  • Processing speed

Display:

  • User interface specifications
  • Result display format

Data Storage:

  • Result storage capacity
  • Data retention

Environmental Conditions:

  • Operating temperature range
  • Humidity specifications
  • Altitude requirements

Power Requirements:

  • Voltage specifications
  • Frequency requirements
  • Power consumption

Dimensions and Weight:

  • Physical dimensions
  • Weight specifications
  • Space requirements

Electromagnetic Compatibility:

  • EMC compliance
  • Interference immunity
  • Emissions standards

Safety:

  • Safety certifications
  • Regulatory compliance

Panel Description:

  • Front Panel: User interface, display, controls
  • Right Side Panel: Access panels, connections
  • Rear Panel: Power connection, interfaces, ventilation

Composition:

  • MEK-6400: Component list and configuration
  • MEK-6410: Component list and configuration
  • MEK-6420: Component list and configuration

Interference Substances:

  • Substances affecting measurement
  • Sample quality requirements
  • Preanalytical considerations

SECTION 2: TROUBLESHOOTING (Pages 2.1-2.40)

Check Procedure Flowchart:

  • Systematic troubleshooting approach
  • Decision tree for problem resolution

Operating Condition and Blood Sample Checks:

Operating Condition Check:

  • Environmental verification
  • Reagent levels
  • System status

Blood Sample Handling Check:

  • Sample collection verification
  • Anticoagulant check
  • Sample integrity

Pre-dilution Sample Preparation Check:

  • Dilution procedure verification
  • Pre-diluted sample quality

Checking the Hematology Analyzer:

Checking Background Noise:

  • Measurement procedure with diluent
  • Parameter data check
  • Acceptable noise levels
  • Reducing background noise procedures
  • Background noise problem resolution

Checking the Reproducibility:

  • Checking procedure with control material
  • Acceptable CV values for each parameter
  • Reproducibility troubleshooting

Checking Accuracy:

  • Accuracy verification procedure
  • Reference material requirements
  • Acceptable accuracy ranges

Parameter-Specific Troubleshooting:

  • Poor WBC reproducibility
  • Poor HGB reproducibility
  • Poor RBC reproducibility
  • Poor PLT reproducibility
  • Poor HCT or MCV reproducibility

Solving Problems from Alarm Messages:

Complete alarm code listing with causes and solutions:

Reagent Alarms:

  • A001: No diluent
  • A005: No detergent
  • A007: No lysing reagent

WBC Channel Alarms:

  • A009: WBC priming error
  • A021-A023: WBC level errors
  • A024-A027: WBC bubble errors
  • A029: WBC clog
  • A030: WBC sample error
  • A031-A032: WBC noise
  • A036-A037: WBC manometer dirty

RBC/PLT Channel Alarms:

  • A010: RBC priming error
  • A041-A043: RBC level errors
  • A044-A047: RBC bubble errors
  • A049: RBC clog
  • A050: RBC sample error
  • A051: RBC noise 2
  • A052: PLT noise 1
  • A053: PLT noise 3
  • A057-A058: RBC manometer dirty

HGB Alarms:

  • A061: HGB voltage low
  • A062: HGB voltage high
  • A063: HGB circuit error

Mechanical Alarms:

  • A072: Tube holder open
  • A073: Tube in the holder

Temperature Alarms:

  • A091: Room temperature high
  • A092: Room temperature low
  • A093: Internal temperature high
  • A094: Internal temperature low
  • A095: Power supply temp high

Result Flags:

  • ! on WBC measured value
  • ! on MCHC measured value
  • C on WBC or PLT (clumps detected)
  • Other quality flags

Solving Problems from System Error Messages:

  • E001: Diluter initialize error
  • E021: Sampler initialize error
  • E041: Sub bath initialize error
  • E101: Bath drain error
  • E122: Check settings
  • E123: Memory error
  • E124: Circuit error
  • E126: Touch panel error
  • E141: Cap pierce initialize error

Service Maintenance Screens:

Displaying the SERVICE Screen:

  • Access procedures
  • Password requirements

CHECK MENU Screen:

  • System diagnostics
  • Component testing

UNIT MAINTE Screen:

  • MD-640V maintenance
  • MS-640V maintenance
  • MS-641V maintenance (MEK-6400 only)
  • MV & PUMP CHK

CONT MEASURE Screen:

  • Continuous measurement mode
  • Background noise monitoring

SETTING MENU Screen:

  • ADV. SETTINGS Screen
  • REAGENT FACTOR Screen
  • USER MAINTENANCE Screen
  • PANIC VALUE Screen (MEK-6400/6410)
  • FLAG SETTINGS Screen
  • BAR CODE PORT Screen
  • UNIT CAL Screen

MONITOR Screen:

  • Real-time system monitoring
  • Parameter displays

X10-CV Screen:

  • Precision monitoring
  • CV calculation display

INITIAL MENU Screen:

  • System initialization
  • Factory defaults

OTHER MENU Screen:

  • Additional functions

PRINT SETTINGS Screen:

  • Printer configuration
  • Output format settings

SECTION 3: BOARD/UNIT DESCRIPTION (Pages 3.1-3.12)

Board and Unit Location:

  • Right side view
  • Left side view
  • Front view
  • Top view
  • Component identification

Major Units:

MC-640V Measuring Unit:

  • WBC aperture
  • RBC aperture
  • HGB optical system
  • Transducer assemblies

MD-640V Combination Syringe Pump Unit:

  • Precision syringe pumps
  • Volume control
  • Dilution delivery

MP-640V Pump Unit:

  • Reagent delivery pumps
  • Vacuum system
  • Pressure control

PV-641V Front Panel Unit:

  • User interface board
  • Display control
  • Touch panel interface

JQ-640V Inlet/Outlet Unit:

  • Sample inlet
  • Waste outlet
  • Tubing connections

JQ-641V/JQ-642V Valve Units:

  • Pneumatic valve control
  • Fluid path switching
  • Reagent routing

MS-640V Sampler Unit:

  • Sample probe assembly
  • Aspiration mechanism
  • Probe positioning

MS-641V Cap Pierce Unit (MEK-6400 only):

  • Tube cap piercing mechanism
  • Closed-tube sampling

MR-640V Rinse Unit (MEK-6410/6420 only):

  • Probe rinse system
  • Carryover prevention

Control Boards:

UT-7192 AMP CONTROL Board:

  • Amplifier control circuits
  • Signal conditioning
  • Gain control

UT-7193 POWER Board:

  • Power supply distribution
  • Voltage regulation
  • Power monitoring

UT-7198 MEASURING Board:

  • Main measurement control
  • Data acquisition
  • Signal processing

UT-7201 HGB AMP Board:

  • Hemoglobin amplifier
  • Photometric signal processing

UT-7202 HGB LED Board:

  • LED light source control
  • Wavelength control
  • Intensity regulation

UT-7200 MIXED PUMP Board:

  • Pump motor control
  • Speed regulation
  • Timing control

UT-7205 PRINTER DRIVER Board:

  • Printer interface
  • Data formatting
  • Print control

Who Needs This Manual?

This Nihon Kohden Celltak service manual is essential for:

  • Biomedical equipment technicians (BMETs)
  • Clinical laboratory service engineers
  • Hospital biomedical engineering departments
  • Medical equipment service companies
  • Laboratory equipment specialists
  • Anyone performing authorized service on Celltak analyzers

Prerequisites:

✓ Qualified biomedical service personnel only
✓ Hematology analyzer service experience
✓ Understanding of clinical laboratory equipment
✓ Electrical and fluid system troubleshooting skills
✓ Knowledge of CBC parameters
✓ Proper tools and test equipment
✓ Safety training for laboratory equipment
✓ Biohazard handling procedures


FILE DETAILS

DetailSpecification
Document Number0634-900086B
Manual TitleAutomated Hematology Analyzer MEK-6400/MEK-6410/MEK-6420 Service Manual
Models CoveredMEK-6400/6410/6420 (C, J, K variants)
Creation DateMay 10, 2007
Modified DateFebruary 5, 2017
ManufacturerNihon Kohden Corporation
Product TypeAutomated Hematology Analyzer (Celltak)
ParametersWBC, RBC, HGB, HCT, MCV, MCH, MCHC, PLT
Pages200 pages
PDF QualityProfessional technical manual with detailed diagrams
File Size7.0 MB
Page SizeA4 (595 x 842 pts)
LanguageEnglish
CreatorPageMaker 7.0J
Producer3-Heights PDF Security Shell 4.5.24.6
PDF Version1.4

 

What Our Customers Say

★★★★★ Live reviews from customers
Loading customer reviews...
0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    🛒
    Recently Purchased
    🕒 verified order