Terumo Terufusion TE-112 Infusion Pump Service Manual (PDF)
$95.00 Original price was: $95.00.$18.95Current price is: $18.95.
Official Terumo TERUFUSION TE-112 Infusion Pump Service Manual PDF. Covers configuration & operation, service parts list, disassembly/assembly/adjustment procedures, fault diagnosis (flow charts, alarms/errors), maintenance checks, and circuit diagramβideal for biomedical engineers and service technicians repairing TE-112 pumps.
Description
Terumo Terufusion TE-112 Infusion Pump Service Manual (PDF) DOWNLOAD

Full Long Description
π©Ί TERUFUSION Infusion Pump TE-112 β Service Manual (PDF)
This is the official Terumo Corporation service manual for the TERUFUSION TE-112 infusion pump, built for trained service personnel. It provides the service workflow you need for safe troubleshooting, accurate adjustments, parts identification, and board-level reference.
β Model Covered
Terufusion Infusion Pump: TE-112
π Table of Contents
5.2 Configuration
5.3 Description of Operations
6. Service Parts List
6.1 Development Drawing
6.2 Service Parts List
7. Procedures for Disassembly, Assembly and Adjustment7.1 Procedure for Disassembly
7.2 Procedures for Assembly/Adjustment
8. Fault Diagnosis8.1 Flow Chart
8.2 Fault Diagnosis in Each Phenomenon
8.3 List of Alarms and Errors
9. Maintenance Check
10. Circuit Diagram
11. Necessary Procedures11.1 New-type temperature sensor board with old-type control board procedure
11.2 Connector reinforcement procedure (control board β DC/DC board)
π§ Key Technical Specs (handy for buyers)
Pump type: Peristaltic finger type
Delivery rate setting ranges:
15/19/20 drops/mL sets: 3β300 mL/h (1 mL/h step); 1β75 drops/min (1 drop/min step)
60 drops/mL sets: 1β100 mL/h (1 mL/h step); 1β100 drops/min (1 drop/min step)
Open loop control: 1β500 mL/h (1 mL/h step) (Terumo special infusion set) / 1β300 mL/h (general-purpose set)
Delivery rate accuracy: Β±10% (delivery control mode and open loop control)
π¨ Alarm / Error Coverage (included)
Includes alarm logic and fault diagnosis support for:
Voltage drop
Air-in-line
Occlusion detection pressure: 39.2β117.6 kPa (0.4β1.2 kgf/cmΒ²)
Door open detection
Delivery rate error
Free-flow detection (drop sensor)
Empty detection
Battery fault (βbatt Cellβ)
Delivery probe faults (βProb Errβ, βProbβ)
π File Details
| Item | Details |
|---|---|
| Manual Name | TERUFUSION Infusion Pump TE-112 Service Manual |
| Models Covered | TE-112 |
| Year | 2009 (approval on cover) |
| PDF Quality | Scanned, readable text |
| Pages | 202 pages |
Service the TE-112 the right wayβthis manual gives you the fault flowcharts, alarm meanings, adjustment steps, and circuit reference you need to diagnose faster and repair confidently. Instant PDF download so you can start immediately.
What Our Customers Say