2004 Daikin Water Chilling Unit Service Manual PDF (Si50-402)
$95.00 Original price was: $95.00.$15.95Current price is: $15.95.
Official Daikin Water Chilling Unit Service Manual (Si50-402, Dec 2004) covering air-cooled and water-cooled chillers (R407C/R22). Includes model specs, installation & test run, control panel/remote controller operation, field settings, operating functions, wiring & piping diagrams, operation limits, and complete troubleshooting by symptoms and malfunction codes.
Description
2004 Daikin Water Chilling Unit Service Manual (Si50-402) PDF DOWNLOAD

Description
This factory Service Manual is built for technicians servicing Daikin water chilling units in the medium/small class. It provides the practical information needed to install correctly, run test operations, configure field settings, verify operating values, and troubleshoot faults using symptom-based checks and malfunction code flowcharts.
β Applied Models (covered ranges)
Air Cooled Packaged H/P Chiller (R407C): UWYP125β750A
Air Cooled H/P Brine Chiller (R407C): UWYP630/750AZ
Air Cooled Packaged Chiller (R407C): UWAP75β750A
Air Cooled Brine Chiller (R407C): UWAP3β30AZ
Water Cooled Packaged Chiller (R407C): UWP90β900A
Water Cooled Brine Chiller (R407C): UWP3β30AZ
Water Cooled Packaged Chiller (R22): UWJ90β900D
ποΈ Table of Contents (Neatly Categorized)
A) Air-Cooled Chillers (Heat Pump / Cooling Only)
Includes models: UWYP125β750A / UWYP190β750AC / UWYPβ¦AYE(Y3) / UWYPβ¦AZ / UWAPβ¦ series
Key chapters include:
List of models
Product specifications
Standard specifications
Wiring diagrams
Piping diagrams
Operating values of functional parts
Operation limits & operation standards
Options list
Installation
Carry-in procedure
Location selection + service space requirements
Water piping procedure
Electrical wiring (remote controller / centralized control connections)
Test run
Checks before test run
Test run procedures (control panel / remote controller)
Daily check items
Control panel / remote controller
Display meanings
Operation procedures
Field settings
Dip switch / slide switch / pushbutton settings
Nighttime low-noise operation, forced pump/fan operation, pump interlock, auto restart, etc.
Functions
Electric symbols & part names
Operation control logic (pump, thermostat conditions, restart protection)
Normal operation control (startup, temp control, EEV control, freeze-up protection, defrost control, etc.)
Troubleshooting
Initial servicing checks
Checking method of operation data
Troubleshooting through symptoms
Troubleshooting by malfunction code (code list + flowchart)
Miscellaneous
Differences from previous units
Main PCB board replacement procedure
B) Water-Cooled Chillers (Cooling Only)
Model families listed: UWP⦠(R407C) and UWJ⦠(R22)
C) Reference Section
Thermistor temperature/resistance characteristics
Pressure sensor voltage characteristics
Pressureβtemperature characteristics of R407C
Technical information on brine
Water quality control
Noise and noise-prevention measures
Measures for snow accumulation / strong winds
Handling plate-type heat exchanger used for chilling units
π File Details
| Item | Details |
|---|---|
| Manual Name | Water Chilling Unit β Service Manual |
| Manual Code | Si50-402 |
| Models Covered | UWYP / UWAP / UWP / UWJ series (see Applied Models list above) |
| Year / Date | December 2004 |
| Refrigerants Covered | R407C and R22 |
| PDF Quality | Factory service manual (technical text + diagrams) |
| Pages | 266 pages |
Stop guessing and service it like a proβthis Daikin factory service manual gives you the wiring/piping diagrams, settings, and troubleshooting logic you need to fix faults fast. Download instantly and get your chiller back online with confidence
What Our Customers Say
π Related Products
Discover more professional manuals for your equipment

Daikin Oil Cooling Unit Model 8 Service Manual - PDF

Daikin 2/3MXL-Q Multi-Split AC Service Manual β Heat Pump Repair Diagnostic PDF

Daikin VRV RXQ/RXMQ Service Manual - PDF Download