★ TRUSTED BY 321,897+ PROFESSIONALS WORLDWIDE
๐Ÿข
Trusted Business
Verified & Licensed
๐Ÿ›ก๏ธ
Virus Free Files
100% Safe Downloads
๐Ÿ”’
Secure Payment
SSL Protected
โšก
Instant Delivery
Available Immediately
Sale!

Siemens ACUSON Sequoia Version 1.3 VA30 Ultrasound Instructions Advanced Imaging and System Reference 2021 PDF

Original price was: $49.95.Current price is: $29.95.

This combined 2021 PDF brings together the Siemens ACUSON Sequoia Version 1.3 VA30 Instructions for Use, Advanced Imaging Manual, and System Reference. It documents system setup, safety, transducers, imaging modes, measurements, advanced applications, DICOM and security configuration, and acoustic output reference material for the ACUSON Sequoia ultrasound system.

Buy now
SKU: SIE-ACUSON-SEQ-VA30-HD-2021 Category: Tags: , , Vendor: Excavator Docs
โšก
Instant PDF Download
Available immediately
๐Ÿ’พ
Save to Your Device
Download & keep forever
๐Ÿ›ก๏ธ
Antivirus Scanned
100% virus-free
๐ŸŒ
Trusted Worldwide
175,000+ customers

Description

Combined ACUSON Sequoia VA30 Documentation in One PDF

The Siemens ACUSON Sequoia Version 1.3 VA30 Ultrasound Instructions Advanced Imaging and System Reference 2021 PDF combines three related publications in one file: the Instructions for Use, the Advanced Imaging Manual, and the System Reference. It is written for the ACUSON Sequoia diagnostic ultrasound system at Product Version 1.3 and Software Version VA30, with a first issue date of 2021-07 and a revision date of 2021-12. Across 838 PDF pages, the set moves from system overview and safety through patient registration, imaging modes, measurements, advanced clinical features, network and DICOM setup, security configuration, and acoustic output tables.

This is a working reference set rather than a brief operator card. The Instructions for Use cover day-to-day system operation and clinical workflow; the Advanced Imaging Manual adds procedure-oriented chapters for biopsy, panoramic imaging, contrast, strain, Virtual Touch, volume imaging, Fusion, physiologic traces, and syngo Velocity Vector Imaging; and the System Reference documents configuration settings, workflow customization, obstetric measurement setup, network connections, DICOM profiles, security administration, patient browser functions, and measurement and calculation label libraries. Together, the three publications support both the person scanning the patient and the person responsible for configuring and maintaining the ultrasound system.

File Details

  • Manual type: User and Reference Manuals: Instructions for Use, Advanced Imaging Manual, and System Reference
  • Product and software: Product Version 1.3; Software Version VA30
  • Brand: Siemens Healthineers
  • System: ACUSON Sequoia diagnostic ultrasound system
  • Language: English
  • Page count: 838 PDF pages
  • File format: PDF
  • Revision date: 2021-12; first issue 2021-07
  • Publication numbers visible: 11511112-ABS-002-01-01 for the Advanced Imaging Manual; 11511112-ABS-003-02-02 for the System Reference

Chapters Covered

  • 1 Introduction: system overview, intended use and indications for use, operating modes, patient target groups, transducers and intended applications, principles of operation, clinical benefits, image screen and touch screen overviews, control panel, trackball, operating mode controls, keyboard, and configuration.
  • 2 Safety and Care: operating safety and environment, serious incident reporting, system symbols and labels, biohazard considerations, fetal examination note, acoustic output, transmit power control, mechanical and thermal indices, imaging functions that change acoustic output, transducer surface temperature, electrical safety, defibrillators, implantable devices, data integrity, daily checklist, maintenance and repair, cleaning and disinfecting, air filter cleaning, disposal, and energy conservation.
  • 3 Transducer Care and Accessories: caring for transducers, cleaning and disinfection methods, immersion levels, approved cleaners and disinfectants, transducer sheaths, brackets and needle guides, storage, and disposal.
  • 4 System Setup: initial setup, ergonomics, control panel and monitor positioning, moving and shipping the system, system startup, power panel, hibernate, monitor settings, touch screen and control panel lighting, audio volume, connecting and disconnecting transducers, protective holders, cable management, accessories, gel warmer, remote assistance, network connections, peripheral equipment, and software updates.
  • 5 Beginning a Study: preventing unauthorized access, logging in, patient registration and preregistration, worklist and local database patient selection, patient registration form fields, patient history, exam and transducer selection, restarting a study, exam packages, activating operating modes, 2D, Doppler, M-mode, color flow, acoustic streaming with cysts, volume imaging overview, capturing images and clips, and completing a patient study.
  • 6 Workflow Protocols: overview, activating protocols, completing protocol views, and editing protocol views.
  • 7 CINE: CINE overview, playback selections, reviewing and adjusting CINE playback, and storing CINE frames.
  • 8 Image Optimization: general imaging parameters, optimizing 2D images, optimizing color images, optimizing Doppler spectra, optimizing M-mode sweeps, and creating user-defined exams.
  • 9 Annotations: annotating with text, directional arrows, and body markers.
  • 10 Measurements and Calculations: activating the measurement function, positioning and anchoring markers, performing and labeling measurements, editing and deleting measurements, viewing results, 2D, Doppler, M-mode, and compound measurement tools, calculations and ratios, obstetric measurements, eSie OB, pediatric hip measurements, and Auto IMT.
  • 11 Cardiac Measurements and Calculations: cardiac measurement labels, 2D, Doppler, and M-mode cardiac tools, measured results, and cardiac units.
  • 12 Reports: overview, modifying reports, obstetric reports, fetal growth charts, entering growth data, pediatric hip reports, saving and transferring report data, and Nuance data transfers.
  • 13 Printing and Recording: printing images, printing reports, customizing print settings, and recording a patient study.
  • Appendix A Technical Description: standard features, operating modes, imaging features, measurements, reports, storage and archiving, mobility, physical dimensions, connections, control panel, monitor, transducer technology, accessories and options, measurement range and accuracy, power and environmental requirements, system classifications, and standards compliance.
  • Appendix B Icons and Indicators: system status indicators, network and remote service icons, keyboard characters, patient information, and imaging parameter displays for 2D, color, Doppler, M-mode, volume, contrast, strain, and Virtual Touch.
  • Appendix C Cybersecurity: ultrasound system security, anti-virus protection, firewall policy, patient confidentiality, security responsibilities, malware prevention, hardening, user accounts and roles, emergency access, physical access, de-identification, data transmission, backup and disaster recovery, audit controls, third-party components, and security product updates.
  • Appendix D Acoustic Output Reference: display resolution and measurement accuracy, Track 3 and IEC 60601-2-37 reporting, summary tables, definitions, and legend.
  • A1 Biopsy and Puncture Procedures: overview, activating the biopsy guideline function, and verifying the needle path before a procedure.
  • A2 Panoramic Imaging: overview, acquiring panoramic images, avoiding artifacts, measuring panoramic images, and technique tips.
  • A3 Contrast Agent Imaging: overview, using contrast agent imaging, burst and flash sequence destruction techniques, configuring the flash sequence, and basic measurements.
  • A4 Modality Compare: overview and comparing images and clips from multiple exams and modalities.
  • A5 Strain Imaging: overview, activation, basic measurements, shadow function, strain ratio, and patents.
  • A6 Virtual Touch Applications: acoustic radiation force impulse technology, point shear wave elastography, Virtual Touch Auto pSWE, Virtual Touch UDFF, measurement labels and data, scanning techniques, liver assessment, and shear wave elastography.
  • A7 Volume Imaging: overview, workflow, setup for volume acquisition, 3D and 4D acquisition, CINE review, visualizing anatomy, positioning and rotating volumes, image layout, magnification, parameter adjustment, multislice, removing data from a volume, storing and printing, measurements, and user-defined exams.
  • B1 Review: overview, activating review, reviewing images, and comparing images.
  • B2 Export and Import: overview, exporting patient data, removing patient-identifying information, editing and sending MPPS data, importing patient data, and virtual workstation confirmation.
  • C1 Physiologic Function: overview, activating physio, connecting leads, ECG and auxiliary ECG traces, adjusting traces, troubleshooting, and configuration settings.
  • D1 Fusion Imaging: overview, terminology, activating Fusion, quality indicators, loading reference data, Fusion Navigator, image display, measurements, real-time imaging, interventional procedures, planning data, image alignment, troubleshooting, tracking system setup, and maintenance.
  • D2 syngo Velocity Vector Imaging: overview, selecting a clip, analyzing views, clip setup, M-mode data display, contour drawing and modification, processing results, bullseye plots, segmental analysis, saving results, and exporting images, clips, and data.
  • System Reference 1 Configuration Settings: system settings, display, patient banner, imaging settings, capture settings, imaging mode settings, image parameter display, annotations, protocols, connectivity and network, peripheral devices, print and store, system management, security, service, and patient browser configuration.
  • System Reference 2 Workflow Configuration Settings: image presets, global image presets, exam association, procedure descriptions, custom annotations, measurement customization, measurement packages, user-defined measurement labels, DICOM structured reporting mapping, reports, and import/export of customized files.
  • System Reference 3 Obstetric Measurement Configuration: reference author selection, custom obstetric tables, default measurement method, and display of fetal information.
  • System Reference 5 Network Configuration: wireless network connections and virtual workstation setup.
  • System Reference 6 DICOM Configuration: local host, DICOM storage, DICOM printers, worklist, verification, export of configuration settings, and certificate import/export.
  • System Reference 7 Security Configuration: security settings, Active Directory domain controller connection, user account management, groups and roles, patient groups, password complexity, and audit trail management.
  • System Reference Appendices: EMC publication, patient browser selections, general measurement and calculation labels, cardiac measurement and calculation labels, obstetric and fetal echo labels, and bibliography.

Read as a set, these chapters give a technician, sonographer, or system administrator a connected path from understanding the ACUSON Sequoia system and its transducers to preparing the machine, registering a patient, selecting an exam and operating mode, optimizing images, taking measurements, producing reports, and configuring advanced and networked features. The Advanced Imaging Manual extends the core Instructions for Use into procedure-specific workflows, while the System Reference supplies the configuration, DICOM, security, and label libraries that support reproducible setup across exams.

Transducers, Modes, and Clinical Workflows Documented

The Instructions for Use identify the ACUSON Sequoia as a diagnostic ultrasound system intended for general imaging, vascular, and cardiac imaging, and the indications statement lists fetal, abdominal, pediatric, neonatal cephalic, small parts, OB/GYN, cardiac, pelvic, vascular, adult cephalic, musculoskeletal, and peripheral vascular applications. The manual also documents the Ultrasonically-Derived Fat Fraction measurement tool for reporting an index that can aid a physician managing adult patients with hepatic steatosis, along with measurement packages for anatomical structures across multiple clinical areas.

Operating modes covered include 2D, 2D with harmonics, 2D with harmonics for contrast agent imaging, color flow Doppler, power Doppler, pulsed wave Doppler, pulsed wave Doppler tissue imaging, high pulse repetition frequency pulsed wave Doppler, steerable continuous wave Doppler for imaging transducers, continuous wave Doppler for non-imaging transducers, M-mode, M-mode with harmonics, anatomical M-mode, strain imaging, shear wave elastography, and 3D/4D volume imaging. Combined modes include 2D with color, 2D with Doppler, 2D with color and Doppler, 2D with M-mode, 2D with M-mode and color, and 2D with elastography.

Transducer coverage in the manual includes array, phased array, endocavity, and continuous wave models, with intended applications and mode support listed for each. The text identifies models such as 7L2, 10L4, 14L5, 18L6, DAX, 5C1, 9C3, 11M3, 18H6, 4V1, 5V1, 8V3, 10V4, 9EC4, 9VE4, CW2, and CW5. It also describes transducer care, immersion levels, approved cleaners and disinfectants, sheaths, brackets, needle guides, and storage requirements.

Safety, Measurements, and System Administration Content

The safety material is detailed and practical rather than a short warning page. It covers acoustic output and transmit power, mechanical and thermal indices, imaging functions that can change acoustic output, transducer surface temperatures, electrical safety, protective earth, defibrillator considerations, implantable device interference, data integrity, cleaning and disinfection of system surfaces, approved disinfectant wipes, air filter cleaning, and disposal. The daily checklist and maintenance sections give the user a routine for inspecting transducers, power cords, ECG connectors, trackball, and controls before use.

Measurement chapters explain 2D distance, depth, ellipse, trace, open trace, angle, and eSieCalcs tools; Doppler velocity, heart rate, D-trace, resistive index, acceleration, time, heart cycle, and auto trace; M-mode distance, slope, heart rate, and time; compound measurements such as area and distance stenosis, volume, and volume flow; calculations and ratios; obstetric measurements including AFI, fetal heart rate, ratios, multiple fetuses, and eSie OB; pediatric hip angle and femoral head coverage measurements; Auto IMT; and cardiac measurement labels and tools for 2D, Doppler, and M-mode. The report chapters then explain how measured values, images, comments, growth charts, and assessments are organized and transferred.

Advanced Imaging and Configuration Reference

The Advanced Imaging Manual is the procedure-oriented portion of the file. It covers needle path verification and biopsy guidelines, panoramic and color panoramic acquisition, contrast agent imaging with burst and flash sequencing, modality compare for prior exams and other imaging modalities, strain imaging and strain ratio, Virtual Touch point shear wave elastography, Auto pSWE, UDFF, shear wave elastography, 3D and 4D volume acquisition and review, multislice review, volume editing, export and import of patient data, physiologic ECG and respiration traces, Fusion imaging with tracking system setup and image alignment, and syngo Velocity Vector Imaging for clip analysis, contours, segmental analysis, bullseye plots, and reporting.

The System Reference is aimed at configuration and administration. It documents image presets, global presets, exam association, procedure descriptions, annotation packages, touch screen layout, measurement packages, user-defined measurement labels, DICOM structured reporting mapping, report templates, obstetric tables, wireless network profiles, virtual workstation setup, DICOM storage and printer profiles, worklist settings, local host settings, certificate import/export, security settings, Active Directory connection, user accounts, groups and roles, patient groups, password complexity, audit trail configuration and archiving, EMC guidance, patient browser options and status legends, and extensive measurement and calculation label appendices for general, cardiac, obstetric, and fetal echo exams.

What This ACUSON Sequoia Manual Set Enables

With this PDF, a user can follow documented procedures for preparing the ACUSON Sequoia system, connecting and caring for transducers, registering patients, selecting exams and operating modes, optimizing 2D, color, Doppler, and M-mode images, annotating and measuring images, producing exam reports, and using advanced imaging features such as panoramic, contrast, strain, Virtual Touch, volume, Fusion, and syngo VVI. Administrators and service personnel can use the System Reference to configure presets, measurement packages, DICOM destinations, worklist connections, network profiles, user accounts, security settings, and audit trails.

Correct procedures and specifications matter because ultrasound work combines patient safety, infection control, acoustic output awareness, reproducible measurements, and secure handling of patient data. Having the Instructions for Use, Advanced Imaging Manual, and System Reference together makes it easier to check the manufacturer-documented setup, measurement label, DICOM, and security details before changing a configuration or performing a clinical workflow.

The file is delivered as an instant PDF download after payment, with no shipping and no physical media. It can be viewed on a computer, tablet, or phone and printed for use in the department or service area.

Reviews

There are no reviews yet.

Be the first to review “Siemens ACUSON Sequoia Version 1.3 VA30 Ultrasound Instructions Advanced Imaging and System Reference 2021 PDF”

What Our Customers Say

โ˜…โ˜…โ˜…โ˜…โ˜… Live reviews from customers
Loading customer reviews...
0
๐Ÿ›’
Recently Purchased
๐Ÿ•’ verified order