Drager Narkomed 6000 Anesthesia System Technical Service Manual – PDF Download

Original price was: $39.95.Current price is: $24.95.

460-page Drager Narkomed 6000 Anesthesia System Technical Service Manual in PDF, covering diagnostics, troubleshooting, field replacement, calibration, PMS procedures, Divan ventilator service, and spare parts.

Buy now
SKU: HD-NM6000-TSM-460 Category: Tags: Vendor: OverhaulDocs
⚑
Instant PDF Download
Available immediately
πŸ’Ύ
Save to Your Device
Download & keep forever
πŸ›‘οΈ
Antivirus Scanned
100% virus-free
🌍
Trusted Worldwide
175,000+ customers

Description

Drager Narkomed 6000 Anesthesia System Technical Service Manual

This Drager Narkomed 6000 Anesthesia System Technical Service Manual is a 460-page technical service reference for the Narkomed 6000 anesthesia system. It is organized for qualified technical service personnel and covers diagnostics, troubleshooting, replacement procedures, adjustment and calibration, Periodic Manufacturer’s Service procedures, system updates, and spare and replacement parts. The manual also includes Divan ventilator service information, Integrated Patient Monitoring Module PMC procedures, and detailed component-level service guidance.

File Details

  • Manual type: Technical Service Manual
  • Brand/model: Draeger Medical, Inc. / Narkomed 6000 Anesthesia System
  • Language: English
  • Page count: 460 pages
  • File format: PDF
  • Part number: 4114846-001
  • Revision: M
  • Date: 23 August 2001

Chapters Covered

The Narkomed 6000 service manual contents are divided into the following sections and major service topics:

  • Section 1: Introduction – recommendations, how to use the manual, general troubleshooting guidelines, warnings and cautions.
  • Section 2: Diagnostics – accessing the service screens, advanced service mode, service monitors notebook, service configuration notebook, service dump notebook, service log, service log entry detail, NM6000 event log transfer using Windows 95/98, event log transfer using Windows NT, alternate event log transfer procedure, Divan ventilator power-up self test, and Divan service mode.
  • Section 3: Troubleshooting – power supply and voltage distribution, battery, and troubleshooting guides for loss of O2 monitor, loss of breathing pressure monitor, loss of respiratory monitor, loss of agent monitor, no audio alarms, serial port communication failure, no oxygen supply pressure alarms, CRT blank, touch screen not responding, ventilator piston-cylinder not working, leak test failure at ventilator start-up, vapor exclusion system sticking, piston-cylinder removal difficulty, and humming noise from the Divan during mechanical ventilation.
  • Section 4: Replacement Procedures – cylinder yoke assemblies, cylinder pressure regulators, cylinder and pipeline pressure gauges, flowmeters, flow control valves, minimum O2 flow cutoff solenoid, auxiliary oxygen flowmeter, oxygen supply failure protection device, oxygen supply pressure alarm switch, oxygen ratio controller, O2 flush valve, ventilator piston-cylinder diaphragm replacement, Divan ventilator PCB assemblies, battery and EPROM replacement, breathing system, breathing system and ventilator lip seals, ventilator replacement, caster, battery, power supplies, processor assembly, VPO assembly, Vitalbus hub PCB assembly, agent analyzer assembly, lithium battery replacement, CRT assembly, flat panel display assembly, table lamp, strip chart recorder assembly, flow sensor, oxygen sensor, lower frame cover, Divan safety plate, WPU motherboard battery, vaporizer mounting and exclusion system, main pneumatic valve, Divan ventilator front bezel and related components, and integrated patient monitor replacement.
  • Section 5: Adjustment and Calibration Procedures – cylinder pressure regulator adjustment, oxygen supply pressure alarm switch adjustment, oxygen ratio controller adjustment, oxygen sensor calibration, breathing pressure monitor calibration, agent monitor sample flow calibration, CRT alignment, flat panel brightness, contrast and phase adjustments, touch screen calibration, advanced touch screen calibration, ventilator supply pressure adjustment, ventilator supply flow adjustment, ventilator control pressure adjustment, breathing system leveling adjustment, bag pole friction adjustment, right vaporizer vertical adjustment, and system electrical switch adjustment.
  • Section 6: PMS Procedure – materials required, periodic manufacturer’s certification general instructions, PM certification procedure, service menu, battery circuit, open reservoir scavenger, scavenger interface A/C, suction regulator, suction switch, high pressure leak, regulator and gauges, oxygen supply failure protection, flowmeters, oxygen analyzer, oxygen concentration tests, oxygen ratio control, fresh gas leak test, minimum O2 control solenoid test, Divan maintenance, Divan service mode, Divan operating mode tests, respiratory volume, pressure monitor, agent analyzer accuracy test, O2 flush valve, reset logbook, electrical safety, vapor exclusion system, table top lamp, flowmeter lights, CRT fan, operator’s instruction manual, and final check.
  • Section 6A: PMS Procedure – Integrated Patient Monitoring Module – electrical safety analysis, ECG tests, battery operation, defibrillator synchronization tests, ST segment analysis, invasive blood pressure, temperature tests, cardiac output tests, SPO2/pulse, NIBP, chart recorder assembly, and final IPMM and strip chart recorder checks.
  • Section 7: System Updates – exclusion system update, gas analyzer modifications, installation of flow sensor anti-rotation bracket, installation of bag arm O-ring, locking knob, and friction screw adjustment, lubrication of ventilator piston rod, and Vitalbus hub conversion to single COM port configuration.
  • Section 8: Spare and Replacement Parts – monitor and touchscreen assembly, flat panel display, table lamp assembly, strip chart recorder assembly, gas analyzer assembly, integrated patient monitoring module, Divan piston-cylinder unit and lip seals, Divan electronics assemblies and batteries, absorber canister and diffuser, Divan breathing system, ultrasonic flow sensor, oxygen sensor, hose assemblies, pipeline inlets, failsafe assemblies, ORC, O2 supply pressure switch, minimum flow O2 solenoid, flowmeter shield, knobs, gauges, auxiliary O2 flowmeter, suction switch, vacuum on/off valve assembly, flow tubes, flow control valves, cylinder pressure regulators, O2 flush valve, bag arm assembly, cylinder yokes, VPO assembly, interface assembly, Vitalbus assembly, power supply, casters, processor and related items, internal cables and wire harness assemblies, open reservoir scavenger, scavenger A/C and vent grill adapter, vapor mounting and exclusion system, and touch-up paint.

As a whole, this Narkomed 6000 technical service manual gives the technician a structured path from on-board diagnostics and service-screen access through fault isolation, assembly replacement, calibration, and PMS verification. It is particularly useful because it brings the electrical and pneumatic systems, Divan ventilator service mode, breathing system components, gas analyzer, VPO assembly, processor, Vitalbus hub, and replacement parts references into one service document for the Narkomed 6000 anesthesia system.

Service Areas Covered in Detail

The diagnostics section explains how to reach the service screens from the monitor, how the service monitors notebook is organized, and how the service configuration, service dump, service log, and event log transfer functions are used. It also documents the Divan ventilator power-up self test and Divan service mode, including the service log, removal position, language selection, system selection, volume adjustment, total hours, operating hours, self test, leak tests, valve test, pressure value display, pressure sensor calibration, hardware I/O, moving the piston, A/D converter, PEEP valve, RS232 tests, PC service mode, select parameter, display configuration, standby setting, confirm mode, and cancel tests.

The troubleshooting section provides a voltage distribution overview for the processor, communication port assembly, system, and ventilator, with test points and acceptable ranges. It also provides battery information and a set of troubleshooting guides keyed to common failure modes and symptoms. These guides support systematic checks for monitor loss, alarm problems, communication failures, oxygen supply pressure alarm issues, CRT and touch screen problems, ventilator piston-cylinder faults, leak test failures, vapor exclusion sticking, piston-cylinder removal difficulty, and Divan humming noise.

Replacement coverage is extensive and field-oriented. It includes gas supply components such as cylinder yokes, regulators, gauges, flowmeters, flow control valves, the minimum O2 flow cutoff solenoid, the auxiliary oxygen flowmeter, oxygen supply failure protection devices, the oxygen supply pressure alarm switch, the oxygen ratio controller, and the O2 flush valve. Ventilator-related replacement procedures include the piston-cylinder diaphragm, Divan PCB assemblies, battery and EPROM replacement, the breathing system, lip seals, complete ventilator replacement, the Divan safety plate, and the Divan front bezel and related components. Electronics and display coverage includes power supplies, the processor assembly, VPO assembly, Vitalbus hub PCB assembly, agent analyzer assembly and lithium battery, CRT assembly, flat panel display assembly, table lamp, strip chart recorder assembly, WPU motherboard battery, and integrated patient monitor replacement.

Adjustment, Calibration, and PMS Coverage

The adjustment and calibration section provides field procedures for cylinder pressure regulators, the oxygen supply pressure alarm switch, the oxygen ratio controller, oxygen sensor calibration, breathing pressure monitor calibration, agent monitor sample flow calibration, CRT alignment, flat panel display brightness, contrast and phase adjustment, touch screen calibration, advanced touch screen calibration, ventilator supply pressure, ventilator supply flow, ventilator control pressure, breathing system leveling, bag pole friction, right vaporizer vertical adjustment, and the system electrical switch.

The PMS procedure section is built around a complete Periodic Manufacturer’s Service workflow. It includes the service menu, battery circuit check, scavenger procedures where applicable, suction regulator and suction switch checks, high pressure leak tests, regulator and gauge checks, oxygen supply failure protection, flowmeter tests, oxygen analyzer checks, oxygen concentration tests, oxygen ratio control, fresh gas leak test, minimum O2 control solenoid test, Divan maintenance, Divan service mode, Divan operating mode tests, respiratory volume, pressure monitor tests, agent analyzer accuracy, O2 flush valve, reset logbook, electrical safety, vapor exclusion system, table top lamp, flowmeter lights, CRT fan, operator’s instruction manual check, and final check. A separate section covers the Integrated Patient Monitoring Module PMC procedure for machines equipped with that module.

System Updates and Parts Reference

The system updates section covers the exclusion system update for specific serial number ranges, gas analyzer modifications, flow sensor anti-rotation bracket installation, bag arm O-ring and locking knob installation with friction screw adjustment, lubrication of the ventilator piston rod, and Vitalbus hub conversion to a single COM port configuration. The spare and replacement parts section lists field-replaceable items, related hardware, cables, assemblies, and reference part numbers, with item numbers keyed to the accompanying illustrations in the manual.

Why This Narkomed 6000 Technical Service Manual Matters

For a technician responsible for the Narkomed 6000 anesthesia system, this manual supports real service work: diagnosing monitor and ventilator faults, interpreting service logs and event logs, replacing field-serviceable assemblies, setting regulators and pressure switches, calibrating oxygen and pressure monitors, performing PMS checks, and verifying electrical safety. The procedures are specific to the Narkomed 6000 and its Divan ventilator, so they help reduce guesswork when working on the gas delivery system, breathing system, electronics, displays, and patient monitoring module.

Having the Drager Narkomed 6000 Anesthesia System Technical Service Manual available as a PDF makes it easy to reference on a laptop, tablet, or phone in the shop or at the machine. It can be printed for bench use, and it is delivered instantly after payment with no shipping and no waiting for a physical copy. Whether you are performing scheduled maintenance, tracking down an intermittent alarm, replacing a pneumatic component, or checking a calibration value, this Narkomed 6000 service manual is a practical service companion.

IMAGES PREVIEW

Drager Narkomed 6000 Anesthesia System Technical Service Manual - PDF Download β€” PDF page 1 preview
Drager Narkomed 6000 Anesthesia System Technical Service Manual - PDF Download β€” PDF page 77 preview
Drager Narkomed 6000 Anesthesia System Technical Service Manual - PDF Download β€” PDF page 142 preview

Reviews

There are no reviews yet.

Be the first to review “Drager Narkomed 6000 Anesthesia System Technical Service Manual – PDF Download”

What Our Customers Say

β˜…β˜…β˜…β˜…β˜… Live reviews from customers
Loading customer reviews...
0
πŸ›’
Recently Purchased
πŸ•’ verified order