GE Mac-Lab CardioLab Centricity Cardiology INW Service Manual 6.9.6 – Full PDF

Original price was: $39.95.Current price is: $24.95.

Complete 362-page GE Healthcare service manual for Mac-Lab, CardioLab, ComboLab and SpecialsLab systems running Centricity Cardiology INW software version 6.9.6 – troubleshooting, electrical safety testing, planned maintenance, FRU replacement procedures and full parts lists in one printable PDF.

Buy now
SKU: GE-MLCL-INW-696-SM-HD Category: Tags: Vendor: Agri Repair Docs
⚑
Instant PDF Download
Available immediately
πŸ’Ύ
Save to Your Device
Download & keep forever
πŸ›‘οΈ
Antivirus Scanned
100% virus-free
🌍
Trusted Worldwide
175,000+ customers

Description

GE Mac-Lab / CardioLab / Centricity Cardiology INW Service Manual – Software Version 6.9.6

This is the complete US-only service documentation for the GE Healthcare Mac-Lab hemodynamic recording system, CardioLab electrophysiology recording system, ComboLab and SpecialsLab platforms running Centricity Cardiology INW software version 6.9.6. At 362 pages it covers the whole installed system rather than a single box: the HP z600 Acquisition computer and its installed boards, the Integrated Electronics Box, the external UPS, the Patient Data Module and PDM Base Station, TRAMNet with the RAC 4A and TRAM modules, the CardioLab II Plus Amplifier with its Catheter Input Modules, the Analog Output Box, the RF Filter Box, CARTO 3 and Vivid interfaces, review workstations, monitors and printers. Everything a field service engineer or hospital biomedical technician needs to inspect, test, diagnose, repair and maintain the system is assembled in one document.

File Details

  • Manual type: Service manual (installation support, troubleshooting, maintenance, replacement procedures, parts list)
  • Brand / manufacturer: GE Healthcare, a division of General Electric Company
  • Product family: Mac-Lab, CardioLab, ComboLab, SpecialsLab
  • Software version covered: 6.9.6 (does not apply to earlier versions)
  • Document number: 2077147-310E EN
  • Revision: E, dated 3 August 2018 (revision history A through E included)
  • Market: US-Only edition
  • Language: English
  • Page count: 362 pages
  • File format: PDF

Chapters Covered

  • 1 Introduction – Manual Information, Intended Audience (Operators, System Administrator, Field Service Engineer), Indications for Use, Types of Systems (Mac-Lab, CardioLab, ComboLab, SpecialsLab), Compliance and Classification, Conventions, Related Documents, Safety Information and Applicable Messages, Responsibility of the Manufacturer and User, Equipment Symbols
  • 2 Equipment Overview – Serial Number Identification, Typical Acquisition System Configuration (Control Room, Procedure Room, IT Control Room Components, Network Connections), Review Workstations (Nurse’s, Remote Review, Pre/Post), Supported Peripheral Devices, System Hardware (HP Computer, Integrated Electronics Box, UPS, Review Workstation, Mobile Workstand, Monitors, PDM, Analog Out and Defib/Sync, PDM Base Station and Mounting Options, TRAMNet, RAC 4A, CardioLab II Plus Amplifier and Catheter Input Module, Equipotential Grounding Box, Accessory Parts List, CARTO System PIU, Analog Output Box, Network Components and Servers), Cabling and Connections, Software
  • 3 Troubleshooting – Inspection, Powering on the Acquisition System, Powering on the Review Workstation, Initial Troubleshooting Inspection, Hardware (General Issues, Acquisition Hard Drive Failure and RAID rebuild, Communication Issues, Barcode Issues, CardioLab II Plus Amplifier), CardioLab Signal Noise and Mac-Lab Signal Noise (surface ECG and intracardiac noise types with corrective actions), Software (CardioImage, Windows 7/2008, Database backup and database checks), GEMS Task Monitor Service, Networking (IP addressing, transfer speed, DNS client and server side), Centricity Cardiology INW Server and Study Puller, CVIS and DICOM Interfaces, HL7 Export to CVIS, Export System Lists Utility, INNOVA CENTRAL/Touch Screen, CARTO 3 System, Vivid System, EtCO2 and Capnostat sensor check, Remote Connectivity – InSite, Log Files and the Log Collector Utility
  • 4 Maintenance – Mac-Lab/CardioLab Service Performance Testing and the FRU Checkout Procedure Table, Tools Recommended, Visual Inspection/Cleaning, Mac-Lab/CardioLab System Electrical Safety Testing (Protective Earthing, Earth Leakage Current, Enclosure Leakage Current, Patient Source and Patient Sink Leakage Current for the CardioLab II Plus Amplifier and the PDM), Checkout Procedure (Mac-Lab SCOP and CardioLab SCOP), TRAM Module Testing, PDM Testing, CardioImage/Image Capture Testing, IEB Testing, Printer Testing, CARTO Testing, Audible Indicators Testing, RF Ablation Testing, Stimulator Testing, DASH/Solar Testing, Remote Operators Terminal Testing, Analog Out Testing, Centricity Cardiology INW Testing, Remote Connection Testing, Planned Maintenance by component, OEM Component Support Locations, Disk Defragmentation
  • 5 EIZO Monitor Configuration – Overview, Monitor Controls, Before You Begin, Reset all Monitor Settings to Default, Turn Off Automatic Brightness Adjustments, Adjust Screen Using Pattern Files, Select Display Mode, Adjust Color Settings (Brightness, Color Temperature)
  • 6 Replacement Procedures – Field Replaceable Units, Qualified Personnel, Special Tools, Damaged in Transit, Lock Out/Tag Out and ESD, Matrox M9140 Quad Video Board, Matrox Helios Video Board, Matrox Solios Video Board, Matrox Odyssey eA Board, SD Card Drive, ADA Drive, DVD Drive, Hard Drive, Memory, Fans, Power Supply, Barcode Scanner, Uninterruptible Power Supply, INW Server G8 and G6
  • 7 Parts List – HP z600 Computer and keyboards by language kit, Integrated Electronics Box and replacement parts by voltage, UPS kits, Review Workstation and isolation transformer, DASH and Solar connection kits, Centricity Cardiology INW G8 and G6 servers, PDM and PDM Base Station cables and mounting hardware, TRAMNet and acquisition cables, Amplifier and Equipotential Grounding Kit, Vivid, MicroPace, RMOT, Ablation, Analog Output, CARTO, Speakers, CO2, Desks, International Power Cords, Monitors and Printers
  • Appendix A – Electrical, Product and Miscellaneous Abbreviations
  • Appendix B – Technical Specifications: Electrical Power, Atmospheric Conditions, Intracardiac ECG, Physical Dimensions, Validated Third Party Software
  • Appendix C – Electromagnetic Compatibility (EMC): immunity pass/fail criteria, emissions and immunity declarations, recommended separation distances
  • Appendix D – Maintenance Record of Results forms for IEB, computer, server, Vivid external trackball, printer, UPS, PDM and PDM Base Station, Mobile Workstand and Electrical Safety Test results
  • Appendix E – PDM Battery and Accessories: battery charging, waking, testing and replacement, ECG, cardiac output, IBP, NIBP, temperature, Nellcor and Masimo SpO2 accessories
  • Appendix F – EU Battery Directive 2006/66/EC

Read as a whole, this service manual works from the outside in. It starts by establishing what each system variant is intended to do and how the pieces are wired between the control room, procedure room and IT control room, then moves into symptom-driven troubleshooting with separate noise diagnosis paths for surface ECG and intracardiac signals, followed by the measured electrical safety tests that every mains-connected assembly must pass after installation, upgrade or repair. The maintenance chapter converts those tests into a checkout procedure matrix keyed to the FRU you replaced, and the replacement chapter supplies step-by-step board, drive, UPS and barcode scanner swaps with the verification steps that follow each one. The parts list closes the loop by tying every assembly back to a GE part number, including RoHS and non-RoHS variants where both exist.

Electrical Safety Testing With Published Limits

One of the most practically useful portions of this GE Mac-Lab CardioLab Centricity Cardiology INW service manual is the electrical safety chapter, because it tells you exactly which assemblies are tested separately and what the pass limits are. The IEB, isolation transformer, CardioLab II Plus amplifier and PDM Base Station are each treated as a mains-connected device under test.

  • Protective earthing resistance must read 0.2 ohms or less for devices and their power cords
  • Earth leakage current limits of 300 microamps for UL 60601-1 compliance and 500 microamps for IEC 60601-1 compliance
  • Enclosure leakage current of 100 microamps in normal condition, with single fault condition limits of 300 or 500 microamps depending on the standard
  • Patient source and patient sink leakage current limits of 50 microamps single fault and 10 microamps normal condition for the amplifier and PDM

The chapter also defines the patient environment as anything within 1.5 m of the patient table surface, which determines whether enclosure leakage must be measured on a component powered by the IEB or isolation transformer. Test setups, switch positions (earth open or closed, polarity normal or reverse) and recording steps are laid out per device, and Appendix D provides blank record sheets so results can be filed as objective evidence.

Troubleshooting That Follows the Signal Path

Rather than a generic fault list, the troubleshooting chapter is organized around the way these systems actually fail. Hard drive failure on the Acquisition system is handled through the Intel Rapid Storage Technology utility, with drive serial number and port recorded before shutdown, followed by a Ctrl+I RAID rebuild and a verification pass. Communication failures distinguish between TRAM and PDM installations, including the fixed 192.168.0.100 address of the Cath Amplifier connection and the conflict that occurs if any adapter on the Acquisition system is set in the 192.168.0.xxx range.

Signal noise is broken out by type with contributing factors and corrective actions for each: power line frequency, baseline drift, muscle artifact, pacing artifact and ablation noise on surface ECG, then the intracardiac equivalents plus unipolar high frequency and mapping system noise. Einthoven’s Theorem is used to localize a bad electrode or leadwire from the pattern of noisy leads, and the manual explains how to bypass the amplifier using the direct stimulator connection on the CIM module when chasing pacing artifact. For the CardioLab II Plus Amplifier, fiber optic cable cleaning and replacement, indicator behavior and the RCV ERR condition are all addressed directly.

Interface and Network Support

The same manual covers the external systems these labs depend on. DICOM configuration is documented for the local system, X-ray and ultrasound remote hosts, and the Modality Worklist and MPPS hosts, with the dicomdiag tool and a patient search test used to confirm connectivity. CARTO 3 states are explained through the icon color on the Real-Time screen, along with IP address conflict resolution, adapter binding order and the file and printer sharing setting needed for CARTO movie transfer. Vivid time synchronization, INNOVA CENTRAL/Touch Screen port 889 checks, HL7 export auditing and the Export System Lists utility for migrating master lists into a CVIS system are all included, as is InSite remote connectivity with the Service Console, FastPoll and proactive error monitoring codes.

Replacement and Parts Identification

Each board procedure follows the same disciplined pattern: shut down, remove AC power, open the side panel, release the retainer, seat the new board, reconnect cables to the correct labelled connectors, restore power and then verify. The Matrox M9140 procedure, for example, specifies which proprietary cable connector feeds Video 1, Video 2 and Video 3 and notes that the 3/7 connector is unused, then verifies the configuration through the Matrox Power Disk multi-display settings. The SD Card Drive procedure calls out pin 1 alignment between the drive cable and the motherboard’s Internal USB 1 header, since reversing the connector can damage the reader. The ADA Drive procedure adds drive letter verification and driver installation, and the UPS procedure ends with a live battery test that confirms the Acquisition system stays powered while the IEB main switch is off.

Buyer’s Note on Scope

This is a service manual written for trained GE Healthcare Field Service Engineers and hospital Biomedical Technicians, not an operator’s manual. It applies only to software version 6.9.6 and does not cover earlier versions. TRAM-RAC, TRAM and CO2 module service procedures are explicitly referred to the documentation that accompanies those devices, and the electrical safety chapter states the same limitation. The publication is the US-Only edition.

What This Manual Lets You Do

With this GE Mac-Lab CardioLab Centricity Cardiology INW service manual in hand you can inspect and power up an Acquisition system or Review Workstation in the correct order, rebuild a degraded RAID array after a drive failure, isolate a noisy ECG or intracardiac channel to a specific electrode, leadwire or ground, configure DICOM and worklist connectivity to a CVIS or X-ray system, run the full electrical safety test suite with published pass limits and record the results, perform planned maintenance and cleaning on every assembly including the PDM and its battery, replace video boards, drives, memory, fans, power supplies, the UPS and the barcode scanner, reconfigure an EIZO S2133 monitor for clinical display, and identify the correct GE part number for nearly every component in the system.

Getting these procedures right matters because the equipment sits in an interventional lab where a miswired analog connection, an untested protective earth path or an incorrectly seated board is not a paperwork problem. Correct specifications, correct test limits and correct cable routing are what keep the system safe and available between cases.

IMAGES PREVIEW

GE Mac-Lab CardioLab Centricity Cardiology INW Service Manual 6.9.6 - Full PDF β€” PDF page 1 preview
GE Mac-Lab CardioLab Centricity Cardiology INW Service Manual 6.9.6 - Full PDF β€” PDF page 37 preview
GE Mac-Lab CardioLab Centricity Cardiology INW Service Manual 6.9.6 - Full PDF β€” PDF page 54 preview

Delivered as an instant PDF download after payment, with no shipping and no waiting. The file opens on any computer, tablet or phone and every page can be printed for bench use, so the electrical safety record sheets in Appendix D and the checkout procedure tables in Chapter 4 can go straight into your service binder.

Reviews

There are no reviews yet.

Be the first to review “GE Mac-Lab CardioLab Centricity Cardiology INW Service Manual 6.9.6 – Full PDF”

What Our Customers Say

β˜…β˜…β˜…β˜…β˜… Live reviews from customers
Loading customer reviews...
0
πŸ›’
Recently Purchased
πŸ•’ verified order