Bayer ADVIA Centaur and Centaur XP Parts and Repair Service Guide 078D0080-02

Original price was: $39.95.Current price is: $24.95.

Workshop-oriented parts and repair service guide for Bayer ADVIA Centaur and ADVIA Centaur XP immunoassay systems, covering cabinetry, modules, probes, PC boards, parts lists, replacement procedures, and service reference material.

Buy now
SKU: HD-BAYER-078D0080-02 Category: Tags: Vendor: Loader Manuals
⚑
Instant PDF Download
Available immediately
πŸ’Ύ
Save to Your Device
Download & keep forever
πŸ›‘οΈ
Antivirus Scanned
100% virus-free
🌍
Trusted Worldwide
175,000+ customers

Description

Bayer ADVIA Centaur and Centaur XP Parts and Repair Service Guide 078D0080-02

This Bayer ADVIA Centaur and Centaur XP Parts and Repair Service Guide 078D0080-02 is a practical service reference for the ADVIA Centaur and ADVIA Centaur XP immunoassay systems. It organizes cabinetry, major subassemblies, replacement procedures, parts lists, PC board connector references, and service safety information into a single document. The guide is written around hands-on service work: identifying assemblies, removing and installing components, verifying operation, and locating part numbers for ordered replacements.

File Details

  • Manual type: Parts and Repair Service Guide
  • Brand: Bayer HealthCare
  • Models covered: ADVIA Centaur and ADVIA Centaur XP immunoassay systems
  • Document number: 078D0080-02
  • Revision: Rev. A
  • Language: English
  • Page count: 558 pages
  • File format: PDF

Chapters Covered

  • Cabinetry for the ADVIA Centaur System: front and back system overviews, A/C input line assembly, top cover, monitor stand, sample entry queue, sample exit queue, electronics module door, sample tip waste area door, cuvette waste area door, lab automation, and parts list.
  • Cabinetry for the ADVIA Centaur XP System: front and back system overviews, A/C input line assembly, top cover, monitor stand, sample entry queue, sample exit queue, electronics module door, corner door, lab automation, and parts list.
  • Cuvette Loader 113339: assembly overview, motor detail, parts list, replacing the cuvette chute solenoid, and verification using diagnostics tools and controller diagnostics.
  • Elevator 571023B: cuvette elevator PC board location, belt clamp detail, motor detail, and parts list.
  • Incubation Chamber 571021B: assembly, wash station cover, sensor detail, TED assembly detail, parts list, replacing bearings, replacing the index pin, replacing TEDs, servo motor and wash station areas, primary reagent compartment and back areas.
  • Index Mechanism 571024B: assembly, sensor detail, motor detail, and parts list.
  • Luminometer 078-K122-01: assembly, sensor detail, motor detail, parts list, replacing the PMT TED, and replacing the PMT assembly.
  • Preheater 078-B059-01: assembly, cuvette pusher detail, sensor detail, motor detail, TED assembly detail, parts list, and replacing preheater TEDs.
  • Ring Loader 572400B: assembly, sensor detail, motor detail, and parts list.
  • Servo Motor 571730B and 571022B: old and new servo motor assemblies, latch detail, new servo motor detail, and parts list.
  • Wash Station 571025D: assembly, acid probe assembly detail, friction pad detail, sensor detail, motor detail, and parts list.
  • Electronics Module fixed configuration 121911D: assembly, backplane PC board, RT SPARC I/O PC board, fixed electronics module layout.
  • Electronics Module slide out configuration 571115B: assembly, backplane PC board, slide out module layout, parts list, replacing the Real Time SPARC PC board, replacing the User Interface SPARC PC board.
  • User Interface Module 078-0103-XX and 078-0330-XX: assembly, parts lists, replacing the hard disk drive, removing and installing the UI module.
  • Application Module 078-0331-XX: assembly and parts list.
  • Power Supply: slide out electronics module supply 571258D, fixed electronics module supply 078-B047-01, parts list, and replacement procedure.
  • Thermal Control PC Module: ADVIA Centaur System 575257E and ADVIA Centaur XP System 078-B109-XX diagrams, parts lists, and replacement procedure.
  • Reagent Fluidics Module 078-B028-01: assembly, 2 mL diluter, Tri-Continent diluter, and parts list for Centaur and Centaur XP systems.
  • System Fluids Drawer: 078-B055-01 for the ADVIA Centaur System and 078-081-01 for the ADVIA Centaur XP System, including wash manifold, diluter details, Tri-Continent diluter detail, sensor detail, and parts lists.
  • Vacuum Pump 572703B and 078-B050-02: assembly and parts list.
  • Waste and Water Drawer: 078-B005-01 for the ADVIA Centaur System and 078-B089-01 for the ADVIA Centaur XP System, including water reservoir, waste reservoir, water pressure pump, caster detail, and parts lists.
  • Primary Reagent Compartment 571111C: assembly, lead screw detail, sensor detail, motor detail, TED detail, parts list, replacing the leadscrew, and replacing TEDs.
  • Primary Reagent Compartment Door 571104B: assembly and parts list.
  • Reagent Barcode Scanner 571103: assembly, belt clamp detail, sensor detail, motor detail, and parts list.
  • Reagent Probe Guide 571110B: assembly, motor detail, and parts list.
  • Reagent Probe 1 571107C, Reagent Probe 2 571108C, Reagent Probe 3 571109C: assemblies, tubing routing, motor details, sensor details, and parts lists.
  • Ancillary Queue 078-B035-01 and 078-B069-01: assemblies, sensor details, motor and pulley details, and parts lists for Centaur and Centaur XP systems.
  • Ancillary Entry 078-B036-01: housing, motor, leadscrew detail, sensor detail, motor and pulley detail, and parts list.
  • Inprocess and Exit Queue 571040B: motor location, motor gap, motor and pulley detail, and parts list.
  • Sample and Ancillary Probe 078-B045-01 and 078-B123-01: motor and belt locations, sample probe assembly, vertical motor locations, ancillary probe assembly, sample diluter, ancillary diluter and sample air pump assembly, diluter details, motor and pulley details, and parts lists.
  • Sample Entry Queue 078-B002-01 and 078-B078-01: motor and belt locations, belt tensioner detail, belt drive detail, magnet detail, motor detail, and parts lists.
  • Sample Exit Pusher 571037B: assembly, sensor detail, motor detail, and parts list.
  • Sample Tip Loader 571036C and 078-B136-01: assemblies, sensor details, motor and pulley details, and parts lists.
  • Sample Tip Waste Area 078-B009-02 and 078-B088-01: assemblies and parts lists.
  • Stat Sample Pusher 571035: assembly, sensor detail, motor detail, and parts list.
  • Universal Rack Option: sample probe, stat sample pusher, sample exit pusher, inprocess queue, rack sensor pusher cable, sample exit queue, sample exit queue rack present sensor, sample exit queue full sensor, sample entry queue, sample entry queue work surface, sample entry queue tensioner, and parts list.
  • Kits and Tools: available kits and service tools.
  • Centaur PC Boards: connector references and sensor functions for sample and ancillary probe horizontal board, inprocess queue tip sensor, ancillary queue sensor, sample probe vertical sensor, ancillary entry, rack loaded sensor, entry queue sensor, low level controller, backplane boards, thermal control boards, servo low level controller, fluid GIOB, wash fluid interconnect, ancillary probe vertical, reagent handling GIOB, rack present, reagent fluid GIOB, exit queue interconnect, stat area, sample and ancillary probe GIOB, sample and ancillary queue GIOB, cuvette elevator, top and bottom luminometer, reagent probe pack-to-pack, sample tip loader, servo motor interface, aspirate probe, preheater, cuvette GIOB, reagent pack LED array, ancillary entry LEDs, tip tray and band, reagent probe heater control and volume detect boards, mixer interconnect, horizontal interconnect boards, reflective chute sensor, system fluid detect, ancillary pack sensor, and sample pressure level sense boards.
  • Appendix A: protecting yourself from biohazards, references, protecting yourself from barcode scanner lasers, laser safety classification of the ADVIA Centaur System, laser safety classification of the barcode scanners, reagent and sample barcode scanners, and hand-held barcode scanner.
  • Appendix B: Bayer authorized representative, limited instrument warranty and service delivery policy, warranty period, information for technical assistance, printing system information, event log, workspace windows, runtime report, calibration data, and contacts.

The manual is built around service execution rather than theory. It supplies assembly-level diagrams, parts lists with reference and part numbers, connector and sensor callouts, motor details, TED details, and step-by-step replacement procedures for high-value subassemblies such as the cuvette chute solenoid, incubation chamber bearings and index pin, incubation chamber TEDs, luminometer PMT TED and PMT assembly, preheater TEDs, power supply, thermal control module PCB, hard disk drive, primary reagent compartment leadscrew and TEDs, and ancillary queue TEDs. It also provides verification steps using diagnostics tools and controller diagnostics where applicable.

Parts identification and PC board reference

A major strength of this guide is the way it ties physical assemblies to part numbers. Each major section includes a parts list, and many sections include separate sensor, motor, TED, belt clamp, pulley, or leadscrew details. For electronics work, the Centaur PC Boards chapter lists connectors, cable numbers, and connected boards or assemblies, along with sensor functions for the sample and ancillary probes, queues, entry systems, cuvette handling, luminometer, reagent probes, fluidics, and thermal control. This makes the guide useful when tracing a fault to a board, cable, sensor, or motor rather than replacing parts by guesswork.

Service and repair scope

The replacement procedures cover removal, installation, and verification for several critical assemblies. Examples include the cuvette chute solenoid with chute full sensor transfer, incubation chamber bearings and index pin, incubation chamber TEDs in servo motor and wash station areas as well as primary reagent compartment and back areas, luminometer PMT TED and PMT assembly, preheater TEDs, the power supply, the thermal control module PCB, the hard disk drive in the UI module, the primary reagent compartment leadscrew, primary reagent compartment TEDs, and ancillary queue TEDs. The guide also includes cautions for electrostatic-sensitive devices, thermal grease application, TED tightening, PMT lens protection, and safe movement of subassemblies during diagnostics.

Who this guide supports

This Bayer ADVIA Centaur and Centaur XP Parts and Repair Service Guide 078D0080-02 is aimed at service work where assembly identification, correct part numbers, and controlled replacement steps matter. It supports troubleshooting at the module level, parts ordering, board and connector tracing, and scheduled replacement of wear or thermal components. The safety appendix adds biohazard and laser safety guidance for service personnel working around sample paths, waste areas, and barcode scanners.

IMAGES PREVIEW

Bayer ADVIA Centaur and Centaur XP Parts and Repair Service Guide 078D0080-02 β€” PDF page 1 preview
Bayer ADVIA Centaur and Centaur XP Parts and Repair Service Guide 078D0080-02 β€” PDF page 19 preview
Bayer ADVIA Centaur and Centaur XP Parts and Repair Service Guide 078D0080-02 β€” PDF page 51 preview

Instant PDF delivery and practical use

With this guide on hand, a technician can identify the correct assembly, locate its parts list, follow the removal and installation sequence, and verify operation using the system diagnostics described in the relevant sections. Correct procedures and part references reduce the risk of damage to TEDs, PC boards, lenses, and precision mechanical assemblies. The document is delivered as an instant PDF download after payment, with no shipping delay, and can be viewed on a laptop, tablet, or workshop computer and printed for bench use.