★ TRUSTED BY 321,897+ PROFESSIONALS WORLDWIDE
🏢
Trusted Business
Verified & Licensed
🛡️
Virus Free Files
100% Safe Downloads
🔒
Secure Payment
SSL Protected
Instant Delivery
Available Immediately
Sale!

GE Dash 2500 Patient Monitor Service Manual (2042481-001, Rev C) – PDF Download

Original price was: $34.95.Current price is: $24.95.

Complete service manual for the GE Dash 2500 patient monitor. Covers all parameters including NIBP, SpO2, ECG, respiration, temperature, and printer. Includes calibration, troubleshooting, and disassembly procedures. Instant PDF.

Instant PDF Download
Available immediately
💾
Save to Your Device
Download & keep forever
🛡️
Antivirus Scanned
100% virus-free
🌍
Trusted Worldwide
175,000+ customers

Description

File Details

  • Manual Type: Service Manual
  • Brand: GE Medical Systems Information Technologies
  • Model: Dash 2500 Patient Monitor
  • Document Number: 2042481-001
  • Revision: C
  • Language: English
  • Page Count: 178
  • File Format: PDF (instant download)

Chapters Covered

  • 1 Introduction

    • Manual Information, Revision History, Purpose, Audience
    • Ordering Manuals, Illustrations
    • Safety Information: Responsibility of Manufacturer, General, Warnings/Cautions/Notes, Equipment Symbols
    • Service Information: Requirements, Equipment Identification
  • 2 Equipment Overview

    • Components: Equipment Description, Configurations
    • Controls and Indicators: Monitor front panel
    • Theory of Operation: NELLCOR & MASIMO SET SpO2, DINAMAP Blood Pressure, Alaris Temperature, ECG/Respiration
    • Host Communication Port, Communication Adaptor Connector, DB15/DB9 Pin Assignments
    • Functional Description of all boards and assemblies
    • System Block Diagram

    Complete PDF Bookmark Tree

    Complete Bookmarks

    The complete bookmarks in the “GE Dash 2500 Patient Monitor Service Manual (2042481-001, Rev C) – PDF Download” are as follows:

    Contentsp. 5
    1 Introductionp. 11
    Manual Informationp. 13
    Revision Historyp. 13
    Manual Purposep. 13
    Intended Audiencep. 13
    Ordering Manualsp. 13
    Illustrationsp. 14
    Safety Informationp. 14
    Responsibility of the Manufacturerp. 14
    Generalp. 14
    Warnings, Cautions, and Notesp. 15
    Equipment Symbolsp. 16
    Service Informationp. 18
    Service Requirementsp. 18
    Equipment Identificationp. 18
    2 Equipment Overviewp. 19
    Componentsp. 21
    Equipment Descriptionp. 21
    Configurationsp. 21
    Controls and Indicatorsp. 21
    Monitorp. 22
    Theory Of Operationp. 24
    NELLCOR® SpO2 and MASIMO SET® SpO2p. 24
    DINAMAP® Blood Pressure and Pulsep. 25
    Alaris® Oral and Rectal TURBO TEMP Thermometryp. 25
    ECG with Heart Rate and Respirationp. 25
    Host Communication Portp. 26
    Communication Adaptor Connectorp. 26
    DB15 / DB9 Connector Pin Assignmentsp. 27
    Functional Descriptionp. 28
    System Block Diagramp. 34
    3 Installationp. 35
    Connectionsp. 37
    Rear Panel Connectionsp. 37
    Power Upp. 37
    Set Up/Configurep. 38
    Setting up the Dash 2500 Monitor for the First Timep. 38
    Configurep. 39
    Mounting Optionsp. 39
    Software Upgradep. 39
    Network set upp. 39
    4 Maintenancep. 41
    Maintenance Schedulep. 43
    Manufacturer Recommendationsp. 43
    Manufacturer Responsibilityp. 43
    Cleaningp. 44
    Periodic Maintenancep. 46
    Integrity of Hoses and Cuffsp. 46
    Long-Term Storagep. 46
    Periodic Proceduresp. 46
    Care of Storage Batteriesp. 47
    Electrical Safety Testsp. 48
    Generalp. 48
    Test Equipmentp. 48
    Safety Resistance Testingp. 48
    Patient (Source) Leakage Current Testp. 50
    Patient (Sink) Leakage Current Testing (Mains Voltage on the Applied Part)p. 52
    Checkout Proceduresp. 53
    Parameter Level Functional Testingp. 53
    Service Mode Operationp. 54
    Service Mode Exitp. 71
    5 Troubleshootingp. 73
    Required Service Equipmentp. 75
    General Troubleshootingp. 76
    Parameter Troubleshootingp. 77
    Error Codesp. 78
    Alarm Code Interpretationp. 78
    System Failuresp. 78
    6 Field Replaceable Unitsp. 83
    Ordering Partsp. 85
    Partsp. 86
    Assembly Drawingsp. 88
    Disassembly Guidelinesp. 96
    Tools Requiredp. 96
    Before Disassemblyp. 96
    Hardware Precautionsp. 97
    Electrostatic Discharge (ESD) Precautionsp. 97
    Remove/Replace Batteryp. 98
    Replace Plastic Front Casep. 99
    Replace Main Board Assemblyp. 100
    Replace DAS Board Assemblyp. 101
    Replace DC2DC Board Assemblyp. 102
    Replace AC2DC Board Assemblyp. 103
    Replace Keyboard and Trim Knobp. 104
    Replace the Invert Boardp. 105
    Replace the AC Inletp. 106
    Replace the Speakerp. 107
    Replace the printerp. 107
    Replace the Pneumatic Pumpp. 108
    Replace the Check Valvep. 108
    Replace the Fanp. 109
    Assemble Network Modulep. 110
    After Assemblyp. 111
    A Technical Specificationsp. 113
    Technical Specificationsp. 115
    General Specificationsp. 115
    NIBP Specificationsp. 117
    GE Healthcare Patentsp. 117
    NELLCOR® Puritan Bennett, Inc. Patentsp. 119
    MASIMO SET SpO2 Specificationsp. 120
    MASIMO® Patentsp. 121
    ECG Specificationsp. 122
    RESP Specificationsp. 123
    HR/Pulse Specificationsp. 124
    TURBO TEMP Specificationsp. 125
    B Test Recordp. 127
    C Configurationp. 133
    Monitor Configuration Modep. 135
    Enter Configuration Modep. 135
    Configure Default Changesp. 135
    Exit Configuration Modep. 136
    D Auxiliary Outputp. 147
    Auxiliary Outputp. 149
    E EMC Compliancep. 151
    Electromagnetic Compatibility (EMC)p. 153
    Guidance and Manufacturer’s Declaration – Electromagnetic Emissionsp. 153
    Guidance and Manufacturer’s Declaration – Electromagnetic Immunityp. 154
    Guidance and Manufacturer’s Declaration – Electromagnetic Immunityp. 155
    Recommended Separation Distancesp. 156
    Compliant Cables and Accessoriesp. 157
    F Connectionp. 159
    Technical Specificationsp. 161
    Product Compatibilityp. 161
    External Connectorsp. 162
    Ethernet Portp. 162
    Service Portp. 163
    LEDsp. 164
    Communication Adaptor Connectorp. 165
    Cleaningp. 166
    Installation Configuration Procedurep. 166
    Preparationp. 166
    Boot Service Menusp. 169
    Preparationp. 169
    Using the Boot Service Menup. 170
    Service Menusp. 172
    Preparationp. 172
    Using the Service Menup. 173
    GE Medical Systems Information Technologies, Inc.p. 178
    8200 West Tower Avenue Milwaukee, WI 53223 USAp. 178
    World Headquartersp. 178
    GE Medical Systemsp. 178
    Information Technologies, Inc.p. 178
    8200 West Tower Avenuep. 178
    Milwaukee, WI 53223 USAp. 178
    Tel: + 1 414 355 5000p. 178
    1 800 558 5120 (US only)p. 178
    Fax: + 1 414 355 3790p. 178
    European Representativep. 178
    GE Medical Systemsp. 178
    Information Technologies GmbHp. 178
    Munzinger Straße 3-5p. 178
    D-79111 Freiburgp. 178
    Germanyp. 178
    Tel: + 49 761 45 43 – 0p. 178
    Fax: + 49 761 45 43 – 233p. 178
    Asia Headquartersp. 178
    GE Medical Systemsp. 178
    Information Technologies Asia; GE (China) Co., Ltd.p. 178
    GE China Technology Parkp. 178
    1 Huatuo Roadp. 178
    Shanghai 201203, P.R. Chinap. 178
    Tel: + 86 21 3877 7888p. 178
    Fax: + 86 21 3877 7451p. 178
    GE Medical Systems Information Technologies, Inc.
    8200 West Tower Avenue Milwaukee, WI 53223 USA
    GE Medical Systems Information Technologies, a General Electric Company, going to market as GE Healthcarep. 178
    www.gehealthcare.comp. 178

  • 3 Installation

    • Connections (rear panel), Power Up
    • First-time Setup: Date/Clock, Configuration, Mounting, Software Upgrade
    • Network Setup
  • 4 Maintenance

    • Maintenance Schedule, Visual Inspection
    • Cleaning: Monitor exterior, display, cuffs, temperature probes, SpO2 sensors
    • Periodic Maintenance: Hose/cuff integrity, long-term storage, battery care
    • Electrical Safety Tests: Ground resistance, leakage currents (source and sink)
    • Checkout Procedures: Parameter functional testing (SpO2, NIBP, ECG, RESP, Temp, Recorder)
    • Service Mode Operation: SpO2 testing, NIBP testing, calibration, overpressure tests
    • Battery testing, fail-safe logic, keypad, sound, communication tests
    • Alarm relay, network testing, country settings
  • 5 Troubleshooting

    • Required tools and test equipment
    • General troubleshooting (power, display, sound, trim knob, communications)
    • Parameter troubleshooting (NIBP, ECG, SpO2, TEMP, printer)
    • Error code interpretation (system, hardware, NIBP, ECG, temperature, SpO2, respiration, recorder)
  • 6 Field Replaceable Units

    • Ordering parts, parts list with FRU numbers
    • Assembly drawings (exploded views of monitor components)
    • Disassembly guidelines: tools, ESD precautions, step-by-step replacement for battery, front case, main board, DAS board, DC2DC board, AC2DC board, keyboard, inverter, AC inlet, speaker, printer, pneumatic pump, check valve, fan, network module
    • After assembly procedures
  • Appendix A – Technical Specifications

    • General specifications (mechanical, weight, environmental, electrical)
    • NIBP specifications (method, ranges, accuracy, overpressure limits)
    • Patents (GE, Nellcor, Masimo)
    • SpO2 specifications (Nellcor and Masimo sensor accuracy)
    • ECG specifications (leads, frequency response, CMRR, pacemaker detection)
    • HR/Pulse specifications
    • Turbo Temp specifications

    IMAGES PREVIEW

    GE Dash 2500 Patient Monitor Service Manual (2042481-001, Rev C) - PDF Download — PDF page 1 preview
    GE Dash 2500 Patient Monitor Service Manual (2042481-001, Rev C) - PDF Download — PDF page 22 preview
    GE Dash 2500 Patient Monitor Service Manual (2042481-001, Rev C) - PDF Download — PDF page 23 preview

  • Appendix B – Test Record – comprehensive checklists for safety, SpO2, NIBP, ECG, RESP, temperature, recorder, battery, fail-safe, keypad, sound, communications, network
  • Appendix C – Configuration – Monitor Configuration Mode: entering, setting defaults, understanding all configuration options
  • Appendix D – Auxiliary Output – analog ECG output connector pinout and specifications
  • Appendix E – EMC Compliance – electromagnetic emissions and immunity declarations, recommended separation distances
  • Appendix F – Connection – network module installation, boot service menus, service menus, Ethernet and serial port pinouts

This official GE service manual gives biomedical technicians and service personnel everything needed to maintain, troubleshoot, and repair the Dash 2500 Patient Monitor to the field-replaceable-unit level. It provides detailed theory of operation, functional block diagrams, calibration procedures (NIBP pressure calibration, overpressure verification, SpO2 testing), and step-by-step disassembly/reassembly instructions with clear illustrations. The manual also covers all communication ports, remote alarm interfacing, and network configuration for Unity integration.

Whether you are performing routine maintenance, diagnosing error codes, replacing a failed board, or verifying electrical safety, this manual delivers the correct specifications, torque values, and test limits. With the GE Dash 2500 Patient Monitor Service Manual, you gain the confidence to service the monitor accurately and safely, reducing downtime and ensuring reliable patient monitoring.

Instant PDF Download – No Shipping – Printable on Any Device

Reviews

There are no reviews yet.

Be the first to review “GE Dash 2500 Patient Monitor Service Manual (2042481-001, Rev C) – PDF Download”

What Our Customers Say

★★★★★ Live reviews from customers
Loading customer reviews...
0
    0
    Your Cart
    Your cart is emptyReturn to Shop
    🛒
    Recently Purchased
    🕒 verified order